Laserfiche WebLink
SANJ O 1` Q U I `IA,II, Environmental Health Department <br /> COUNTY <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> J B HUNT TRANSPORT INC 2660 LOOMIS RD, STOCKTON January 18, 2019 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 710 CFR 112.8(c)(6)Plan failed to adequately discuss procedures to test or inspect each container for integrity. <br /> The SPCC plan references the Steel Tank Institute (STI)SP-001 industry standard for inspections of the tanks. The <br /> SPCC plan does not address annual inspections as required by the STI SP-001 standard.An environmental <br /> equivalence claim addresses the required testing by certified STI SP-001 inspector and not the deviation from <br /> annual inspections by the facility. Each aboveground container shall be tested and inspected for integrity on a <br /> regular schedule and whenever repairs are made. The qualifications of personnel performing tests and inspections, <br /> frequency and type of testing and inspections that take into account container size, configuration, and design shall <br /> be determined in accordance with industry standards. Examples of these integrity tests include, but are not limited <br /> to:visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic emissions testing, or other <br /> systems of non-destructive testing. Comparison records and other records of inspections and tests must be <br /> maintained on site. Immediately amend the SPCC plan to include inspection/testing as required by the selected <br /> industry standard, or provide equivalence as allowed by CFR 112.7(a)(2). <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by February 17, 2019 . <br /> Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($152). To schedule an <br /> appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received <br /> by: Date: January 18, 2019 Inspector: Inspector Phone: <br /> Printed Name and Title: CESAR RUVALCABA, REHS (209)953-6213 <br /> Shawn Phillips, Maintenance Supervisor <br /> FA0007705 PR0528418 SCO01 01/18/2019 <br /> EHD 28-01 Rev.09/27/2018 Page 5 of 5 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />