Laserfiche WebLink
Anheuser-Busch/Arch Road <br /> Site Safety Plan <br /> February 11, 1992 <br /> 2.0 INFORMATIONAL summRY <br /> 2.1 Health and safety summary <br /> Chemicals of Concern: Gasoline, Benzene, Toluene, .Ethylbenzene, . & <br /> Xylene <br /> Hazard Determinations Serious Moderate Low X <br /> Minimum Level of Protection: <br /> Modified Level D is the minimum. acceptable level for this- site. <br /> Action Level for Upgrading Personal Protection: Upgrade from Level <br /> D to Level C (half face cartridge respirator at 50 ppm air <br /> concentration, full face cartridge respirator at 100 ppm air <br /> concentration) , measured within the breathing zone. This should be <br /> determined by a photo-ionization .,detector (PID) with a 10.2 lamp or <br /> a flame ionization detector (FID) . <br /> Air Monitoring Requirements: <br /> PID X <br /> OVA <br /> FID <br /> OZ/LEL <br /> DETECTOR <br /> TUBES <br /> OTHER <br /> 3 <br />