Laserfiche WebLink
MONffTOR ING WELL SAMPILffNG DATA <br /> Protect Mame Shop 10 Maintenance Sta Project Number 58475-06-24 <br /> ' Well No MW-14 Date 5/9/02 <br /> Well Diameter 4 in Field Personnel JE <br />' Casing Length 74 54 feet Screened Casing Length <br /> Well Elevation feet MSL measured from <br /> tPURGE CHARACTERISTICS <br />' Water Depth Before Purging 48 51 ft 2 in = 1632 Gal/ft 4 in = 6528 Gal/ft <br /> Calculated Water Column Volume 16 99 Gal Volumes Purged 3 0 <br />' Start Purging Time 1336 End Purging Time 1353 <br /> Total Time 17 min Flow Gauge to <br /> Total Volume Pumped 51 Gal Avg Flow Rate 3 0 gpm <br /> Water Depth After Purging feet Time <br /> SAMPLING CHARACTERISTICS <br /> tPurging Method Submersible Pump Sampling Method Disposable Bailer <br /> Laboratory Analysis TPHg,TPHd, BTEX, 5 FOCs by EPA Test Method 8260 <br />' TIME TEMPERATURE I CONDUCTIVITY pH Gallons <br /> °C (umhos/cm) Purged <br /> 1341 23 3 592 721 17 <br />' 1346 233 584 7 14 34 <br /> 1353 234 578 707 51 <br /> 1 <br /> 1405 Sample <br /> Comments Purge water turbid, strong odor <br /> [:T:ur�bidit �- 012�ntu � <br /> i <br /> I <br />�l <br />