Laserfiche WebLink
WELL PURGING AND SAMPLING DATA <br /> WELL NO MW-1 <br />' DATE 219198 PROJECT NAME STOCKTON MAINT YARD PROJECT NO 575-71017 <br /> WEATHER CONDITIONS Rain <br />' WELL DIAMETER (IN ) ❑ 1 [] 2 ■ 4 ❑ 6 ❑OTHER <br /> SAMPLE TYPE ■GROUNDWATER ❑WASTEWATER ❑SURFACE WATER ❑OTHER <br /> WELL DEPTH (TOC) 100 FT DEPTH TO WATER BEFORE PURGING 5672 FT <br />' LENGTH OF WATER 43 28 F CALCULATED 3 WELL VOLUMES 8440 GAL <br /> PURGING DEVICE Grundfos Pump ❑ DEDICATED ❑ DISPOSABLE DECONTAMINATED <br /> SAMPLING DEVICE ❑ DEDICATED 0 DISPOSABLE DECONTAMINATED <br />' EQUIP DECON ❑TAP WATER WASH ❑ ISOPROPANOL ❑ ANALYTE FREE FINAL RINSE <br /> ■ALCONOX WASH ❑ DIST/DEIGN 1 RINSE ❑OTHER SOLVENT ❑ DIST/DEION FINAL RINSE <br /> ❑ LIOUINOX WASH ■ DISTIDEION 2 RINSE ❑TAP WATER FINAL RINSE ❑AIR DRY <br />' CONTAINER PRESERVATION ❑ LAB PRESERVED ❑FIELD PRESERVED <br /> WATER ANALYZER MODEL& SERIAL NO Hydac <br />' ACTUAL CUMUL TEMP SPECIFIC pH DISS TURBIDITY WATER REMARKS <br /> TIME VOLUME 0°F CONDUCT OXYGEN (NTUS) APPEAR (EVIDENT ODOR COLOR PID) <br /> (MIN) PURGED D°C CL=CLEAR <br /> (GAL) CO=CLOUDY <br /> TU=TURBID <br /> INITIAL <br />' 28 68 4840 864 Slight HC odor <br /> 56 68 4900 1198 It Tan <br /> 84 675 4870 892 <br /> rDEPTH TO WATER AFTER PURGING(TOC) FT SAMPLE FILTERED ❑ YES ■ NO SIZE <br /> NOTES Good Recharge SAMPLE TIME 1300 ID# <br /> DUPLICATE ❑ TIME ID# <br /> EQUIP BLANK ❑ TIME ID# <br /> PREPARED BY Chris Merritt <br /> A 1 FOOT LENGTH OF WATER=0 05 GAL IN 1 DIA PIPE 0 17 GAL IN 2 DIA PIPE 0 65 GAL IN 4 DIA PIPE 1 5 GAL IN 6 DIA PIPE <br />