EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BEECHNUT
>
990
>
2900 - Site Mitigation Program
>
PR0506314
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2019 2:40:51 PM
Creation date
2/6/2019 2:20:37 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0506314
PE
2960
FACILITY_ID
FA0007342
FACILITY_NAME
CHEVRON PIPELINE PROPERTY
STREET_NUMBER
990
STREET_NAME
BEECHNUT
STREET_TYPE
AVE
City
TRACY
Zip
95376
APN
23407006
CURRENT_STATUS
01
SITE_LOCATION
990 BEECHNUT AVE
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
56
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' approximately 1,350 yd3; the maximum excavation volume is anticipated to be approximately <br /> 1,350 yd3, so the soil mound is of an adequate volume for backfill of the proposed excavation. <br /> The soil mound was sampled in previous investigations. A total of 5 soil samples were <br /> collected from 3 boring locations by AMEC (GMX-07, GMX-21, and GMX-22; collected in 2001 <br /> ' and 2003), and two soil samples were collected from one boring location by Dames & Moore <br /> (B-1; collected in 1988). The five AMEC soil samples were found to have concentrations of <br /> COCs less than both the residential and commercial/industrial ESLs based on direct contact <br /> ' (Table 4). The two Dames & Moore samples were only analyzed for TPH as oil and grease <br /> (TPHog), with one sample being non-detect, and one sample having a low detection of 65 <br /> milligrams per kilogram (mg/kg) of TPHog. According to the Department of Toxics and <br /> rSubstances Control's "Information Advisory—Clean Imported Fill Material" (August 2001), the <br /> number of samples and analytical testing methods collected from the soil mound are <br /> sufficiently adequate to characterize soil for re-use as backfill. Backfill material will be placed in <br /> loose lifts less than eight inches thick and compacted to at least 90 percent of the maximum <br /> dry density as determined by ASTM D 698. An AMEC staff engineer will observe placement <br /> and compaction of the backfill material and perform density tests at representative locations to <br /> confirm that adequate compaction is obtained. The Site will be graded to maintain current <br /> ' drainage. Figure 7 shows the potential post-excavation and grading site topography, <br /> assuming the maximum excavation is required. <br /> 5.2.4 Dust Monitoring <br /> During remediation activities, dust control measures will be implemented. These measures <br /> include covering soil stockpiles, watering construction areas, and street sweeping. <br /> Windscreens will be utilized on the Site perimeter fence in the vicinity of the excavation (in the <br /> southwest portion of the Site). Additionally, the contractor will continuously monitor airborne <br /> dust at the upwind and downwind site perimeters during all potential dust-generating activities <br /> (i.e., operation of heavy equipment, excavation, stockpiling, and loading) using direct-reading <br /> instruments (e.g., Mini-Ram pDR 1000TM) for measurement of total suspended particulate <br /> matter. Electronic data logs of real-time measurements will be used to determine the <br /> maximum and average dust concentrations at the upwind and downwind perimeter monitoring <br /> locations. If the daily average from any day exceeds 50 micrograms per cubic meter(pg/m3)1 <br /> above upwind concentrations, corrective actions will be taken to increase dust control. <br /> No permits or dust control plans are required by the San Joaquin Valley Air Pollution Control <br /> District (SJVAPCD), due to the relatively small size of the excavation and grading (<5 acres). <br /> ' In accordance with SJVAPCD Rule 8021 — Construction, Demolition, Excavation, Extraction, <br /> ' AMEC Geomatrix Inc <br /> I:\Doc_Safe\6000s\6628.001\3000 REPORTS\Excavation Work Plan-8.12.08\1 Text,cover and slips\Text.doc 8 <br />