Laserfiche WebLink
Page 3 of 4 <br /> thanks. <br /> From: Mike Infurna [EH] <br /> Sent: Tuesday, June 02, 2009 11:34 AM <br /> To: dlbrown@shellopus.com <br /> Cc: jneely@CRAworld.com; Jim Barton <br /> Subject: Shell MW destructions 3011 Ben Holt Drive Stockton <br /> Denis, <br /> I have reviewed Well Destruction Work Plan dated May 29, 2009 <br /> submitted by Conestoga-Rovers and provide this conditional approval to <br /> the well destruction processes described in the plan. <br /> 1 . Due to the presence of MtBE exceeding the MCL at the last sampling <br /> event, December 2007, 4" PVC MW-1 and MW-2 are to be 'over-bored' to <br /> total depth (at least 23' bgs) of initial construction with no less than <br /> 10" augers . <br /> 2. The other 15 wells may be grouted in place as described in the <br /> plan with the condition adequate pressure is applied to the grout column <br /> after its introduction into the casing and maintained long enough for <br /> sealing materials (cement grout) to properly set. [SJ County Well <br /> Ordinance, 13.17.10]. <br /> With the inclusions of#1 and #2 above, the work plan is approved. <br /> Please submit a Well Permit Application Form (and LCD) and $60 fee per <br /> each of the three parcels involved. Provide a signed access agreement <br /> from the land owner for the parcel where MW-5 and MW-13 are located <br /> as well as a State of California Cal Trans encroachment permit for MW- <br /> 10, MW-11 , & MW-12. <br /> You may use this website page for the application form: <br /> http://www.sjgov.org/EHD/docs/pdf/WELL-PERMIT-APPL.pdf <br /> If you have any questions, please contact me by return email or at the <br /> phone number listed below. <br /> thank you. <br /> Michael J. Infurna Jr. <br /> Senior REHS. CA Reg #5649 <br /> LOP/Site Mitigation Unit IV <br /> San Joaquin County Environmental <br /> Health Department(SJCEHD) <br /> 600 E. Main Street <br /> Stockton, CA. 95202-3029 <br /> 6/12/2009 <br />