Chevron Products Company 2 <br /> Chevron Service Station#9-4275.2905 Benjamin}dolt Drive,Stockton,CA April 13,2001 <br /> . Air Sparging System <br /> The AS system is comprised of nine AS wells GM-1 through GM-9 and a 1.5-h <br /> Y P <br /> E g ) P <br /> rotary vane compressor. The AS system alternately injects air into wells GM-1 through <br /> GM-5 and wells GM-6 through GM-9. <br /> During the reporting period, the AS system was 63% operational. The AS system <br /> operated at a flow rate of 13.4 cfm and an injection pressure of 9.4 pounds per square <br /> inch gauge (psig). Remedial system field data sheets are presented in attachment A. Air <br /> sparge operational data, including flow rate and applied pressure data, are presented in <br /> Table 1. <br /> Dissolved oxygen (DO) concentrations were not measured during the first quarter, 2001 <br /> monitoring and sampling event but will be recorded during future monitoring events. <br /> Historical DO concentrations are summarized in Table 2. <br /> Conclusions <br /> The SVE system will remain shutdown until water levels drop to expose a sufficient <br /> length of screen in the SVE wells. The AS system will continue to be operated to inject <br /> air into the groundwater and provide oxygen for biodegradation. <br /> If you have any questions or require additional information, contact Scott Gable at (916) <br /> 861-0400 X 231 or Mr. Robert Cochran at (925) 842-9655. <br /> Sincerely, <br /> SECOR International Incorporated <br /> Greg McIver�) <br /> Project Scientist <br /> l <br /> Cott Gable <br /> Senior Geologist <br /> Attachments: Table 1 - Air Sparge System Operational Data <br /> Table 2 - Dissolved Oxygen Well Concentrations (mg/L) <br /> Figure 1 - Site Location Map <br /> Figure 2 - Site Plan <br /> Attachment A—Remedial System Field Data Sheets <br /> cc: �Ms. Ldri Duncan; San Joaquin Environmental Health Department <br /> 'Mr. Mark List,Regional Water Quality Control Board <br /> 1AChevronk942751Periodic Monitoring12001 O&M19-4275 O&M EQ01 Report.doc <br />