Laserfiche WebLink
ge1ofl <br /> 0 Table <br /> Soil Vapor Extraction System Performance Data <br /> ARCO Service Station#2133 <br /> 2908 Benjamin Holt Drive Stockton California <br /> TPH as Gasoline Benzene <br /> FID influent influent <br /> Hour Meter Blower Average Concen- Removal Net Removed Concen- Removal Net Removed <br /> Sample Date Reading Vacuum Flow Rate Influent Effluent tration Rate Removed to Date tration Rate Removed to Date <br /> ID Sampled (hours) ("H20) (scfm) (ppmv) (ppmv) (ppmv) (lbs/day) (pounds) (pounds) (ppmv) (lbs/day) (pounds) (pounds) <br /> INFL 01/25/00 a — — 4,815 60 4 <br /> INFL 02/15/00 - — 4,815 60 4 <br /> INFL 03114100 — b 30 132 5 0 392 02 00 4 815 008 3 4E-03 00 604 <br /> INFL 04103100 0 c 40 197 4 0 ND 00 10 4 816 003 1 9E-03 003 604 <br /> INFL 04/26100 552 26 188 2 0 ND 10 48 4 821 002 1 3E-03 002 604 <br /> INFL 05/25/00 704 40 167 4 0 ND 00 95 4 825 004 1 8E-03 005 605 <br /> INFL 06129/00 1 544 41 187 9 0 433 0 3 1 5 4 827 ND 00 003 605 <br /> INFL 07/27/00 2,053 47 246 22 0 3070 3 0 354 4,862 048 3 7E-02 039 609 <br /> INFL 08/31100 2 529 70 170 6 0 ND 00 299 4 892 003 1 3E-03 038 613 <br /> [NFL 09/27100 3 177 41 195 7 0 ND 00 00 4 892 ND 00 002 61 3 <br /> INFL 10/23/00 3 804 d 30 329 0 0 ND 00 go 4 892 ND 00 000 613 <br /> INFL 11120100 3,804 d — — 0 0 — 00 00 4 892 — 00 000 613 <br /> INFL 12114100 3,804 d — — 0 0 00 00 4 892 00 000 613 <br /> INFL 01116101 3 804 d -- — 0 0 — 00 00 4 892 — 00 000 613 <br /> INFL 02113101 3 805 a 40 175 11 0 ND 00 00 4 892 0 02 1 2E-03 0 00 61 3 <br /> INFL 03/01101 3,958 d -- 11 0 — 00 00 4 892 -- 1 2E-03 001 613 <br /> 04/03/01 SVES shut down <br /> REPORTING PERIOD THIRD QUARTER 2003 <br /> TOTAL POUNDS REMOVED 4,8972 61 3 <br /> TOTAL.GALLONS REMOVED 8028 84 <br /> PERIOD POUNDS REMOVED 00 00 <br /> PERIOD GALLONS REMOVED 00 00 <br /> PERIOD AVG FLOW RATE 175 <br /> PERIOD PERCENT OPERATIONAL 0% <br /> scam =Standard cubic feet per minute a Data prior to 1998 was reported by Brown&Caldwell <br /> lbs =Pounds b System startup <br /> — =Not available or not applicable c Hour meter installed 413100 <br /> ND =Non-detectable above detection limit d SVE system turned off due to low influent concentrations <br /> ppmv =Parts per million by volume a SVE restarted <br /> TPH =Total petroleum hydrocarbons Density of benzene=7 34 pounds per gallon <br /> FID =Flame ionization Detector Density of gasoline=6 1 pounds per gallon <br /> "H20 =Inches of water <br /> 778P 52133 00 019010&M Tables 3Q03 As/Table A-1 <br />