SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
3500 - Local Oversight Program
>
PR0544111
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 11:13:05 AM
Creation date
2/7/2019 10:30:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0544111
PE
3528
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
02
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
94
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Stantec <br /> Site History and Previous Investigations <br /> Chevron and ARCO Commingled Plume No. CP0034 <br /> October 26, 2011 <br /> zone or depth intervals showing distinct pore pressure. Three to four depth-discrete <br /> groundwater samples per boring were submitted for analysis. Groundwater samples were <br /> generally collected at depths of ten to 12 feet (ft) below ground surface (bgs), 24 to 25 ft bgs, 35 <br /> to 40 ft bgs, and 68 to 78 ft bgs. GRO was detected in two of the 17 groundwater samples at <br /> concentrations of 73 micrograms per liter (µg/L) (CPT-5 at 37 ft bgs) and 130 gg/L (CPT-3 at 40 <br /> ft bgs). Methyl tert-butyl ether (MTBE) was detected in six of the 17 groundwater samples at <br /> concentrations ranging between 0.59 gg/L (CPT-4 at 10 ft bgs) and 2.6 gg/L (CPT-5 at 37 ft <br /> bgs). <br /> The site was demolished and five USTs were removed in June 2005. Two new USTs (30,000 <br /> and 15,000 gallons), dispenser islands, and a station building were constructed in June 2005. <br /> In preparation for site demolition, seven on-site groundwater monitoring wells (MW-1 through <br /> MW-5, MW-7, and MW-9) and ten SVE/AS wells (VW-1, GM-1 through GM-8, and GM-9) were <br /> destroyed in May 2005. Replacement monitoring wells were installed in February 2006 following <br /> completion of the station rebuild, as proposed in the SECOR International Incorporated <br /> (SECOR) Work Plan for Well Destruction and UST Removal, the Work Plan for Soil and <br /> Groundwater Delineation, and Addendum to Work Plan for Well Destruction and UST Removal <br /> (SECOR, 2005). <br /> On June 11, 2007, SECOR field staff observed WDC Exploration and Wells of Zamora, <br /> California (WDC) drill and install MW-10 to approximately 20 ft bgs using a CME-75 drill rig <br /> equipped with an 8.25-inch hollow-stem auger. MW-10 was constructed with two-inch diameter <br /> schedule 40 polyvinyl chloride casing extending from ground surface to approximately five ft bgs <br /> and two-inch diameter schedule 40 polyvinyl chloride casing with 0.020-inch slotted-screen <br /> extending from approximately five to 20 ft bgs. Petroleum hydrocarbons were not detected in <br /> any soil samples collected from MW-10. <br /> During the summer of 2011, the municipal well on the northeast corner of Ben Holt and <br /> Plymouth Road was decommissioned. <br /> Remedial Performance Summary <br /> An AS system was activated in April 1997 and an SVE system was activated in September <br /> 1997. The AS system consisted of a 1.5-horsepower (hp) rotary vane compressor, alternately <br /> injecting air into nine wells (GM-1 through GM-9). The SVE system was comprised of ten SVE <br /> wells (VW-1 and GM-1 through GM-9), a five-hp positive-displacement blower, and 100-cubic ft <br /> per minute (cfm) catalytic oxidizer. The SVE system was deactivated due to high groundwater <br /> levels on February 1998. Upon shutdown of the SVE system, the system extracted <br /> approximately 70 pounds (Ibs) of GRO from the soil and groundwater beneath the site. The SVE <br /> and AS wells were destroyed and the remediation equipment was removed from the site in May <br /> 2005. ' <br /> ARCO 2133 Facility <br /> Four USTs, associated product lines, and dispensersare present at the site. A release from a <br /> pipe leak was discovered in 1984. release of approximately 2,000 gallons of gasoline was <br /> reported in May 1989, and an unknown quantity of fuel was released at the northern dispenser <br /> island in 1995. ,pAq L5 S/261 clj <br /> 1 V <br /> (q3-"�N-) <br /> 94275 Site History and Previous Investigations.doc 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.