Laserfiche WebLink
J. i he discharger shall pro- <br /> L3877 February 18 vide a recordm9 lower CERT1FtCATE <br /> ORDINANCE NO.009-89C.S explosive limit(LEL)moni- This is to certify that Ordi• <br /> AN ORDINANCE AMENDING tor.Installation will be at a nance No. DO9-89C.S. was <br /> CHAPTER 7 OF THE STOCK• location in thedischarge passed to print by the City <br /> TON MUNICIPAL CODE BY system prior to entry into Council of the City of Stockton, <br /> . g <br /> ADDING SECTION 7-0892br <br /> 0, the sanitary sewer. The on the 14th day of Feuary <br /> REGARDING DISCHARGE OF monitor is to be calibrated 1989by the followinvote <br /> PETROLEUM CONTAMINATED in a manner that indicates AYES: Counciimembers <br /> GROUNDWATER TO THE SANI- the Percentage of LEL of Bonner.Clayton, Lang. Linner- <br /> TARY SEWER COLLECTION gasoline and shall be con- man, Mc aughey, Oliva, <br /> SYSTEM netted to the facility in Weaver,Vice Mayor Coale and <br /> BE R ORDAINED BY THE such a way that an alarm M orFass <br /> will be tirnered at- NAS:NONE <br /> CITY COUNCIL OF THE CITY OF he LEL 0/gasoline and the ABSENT:NONE <br /> STOCKTON,AS FOLLOWS: n auto- Stockton, Cat., February 15, <br /> SECTION I.FINDINGS. matically shut down. The 1989 <br /> The City Council finds and monitor shall be calibrated /s/FRANCES HONG <br /> declaresthat leaking under- and maintained with a qual- <br /> ground petroleum storage tanks ity assurance program sat- Gry of$I°ocktorej <br /> pose a potential threat to the ISfactory to the Director of <br /> safety, integrity, and quality of Municipal Utilities. If, after <br /> the groundwater supply upon a period of evaluation,it is <br /> which the citizens of the City of determined by the Director <br /> Stockton depend for drinking of a designated revresanta- <br /> water.The Council further finds five that continuous record- <br /> and declares the necessity for ing is no longer needed.the <br /> owners of leaking underground provision of a recorder may <br /> petroleum storage tanks to take be deleted. <br /> necessary steps to remove 4.The Director or a desig- <br /> such tanks,to clean up sources nated representative shall <br /> of groundwater contamination, have access to the facility <br /> and to property dispose of shutdown switcha5 we11 as <br /> petroleum contaminated copies of keys to all locked <br /> groundwater. Therefore. it is enclosures at the site and <br /> necessary to establish regula- shall be Provided access to <br /> tions for the proper disposal of the facilityfor <br /> purposes of <br /> petroleum contaminated inspection <br /> groundwater into the sanitary 5.The discharger shall pro- <br /> sewer collection system. vide flow monitoring and <br /> SECTION If. AMENDMENT OF recording equipment_and <br /> CODE. sampling taps or equipment <br /> Chapter 7 of the Stockton in order to comply with <br /> Municipal Code is herebyy these rules. <br /> amended by addingSection 7- 6.The discharger shall insure <br /> 089.20 which shabe as tot- that all Pretreatment lacili- <br /> lows: ties including, but not lim- <br /> SECTION 7-089.20. DIS- ited to.flow measuring and <br /> CHARGE OF PETROLEUM CON- LEL monitors. are main- <br /> TAMINATED GROUNDWATER: Aained in proper working <br /> It shall be urnawful for any per- order at all times.All mea- <br /> son to discharge petroleum suring devices are to be <br /> Contaminated groundwater to calibrated for accuracy at a <br /> the sanitary sewer collection frequency as Prescribed by <br /> system of the Qty of Stockton, the manufacturer of the <br /> except as provided for hereon, monitoring device by a <br /> der,and in accordance with the qualified technician <br /> following . conditions and approved by the Director. <br /> restrictions: 7.In the evert a required flow <br /> 1.The maximum allowable measuring device is found <br /> concentration of total petro- to be inoperative or to pro- <br /> leum hydrocarbons in the vide unreliable information <br /> discharge ente mp the sani- as determined by the Direc- <br /> tary sewer shall be 1D for or a designated repre- <br /> mg/L.Compliance with this sentative, maximum vol- <br /> Provision will be enforced roves will be used for <br /> by periodic sell-monitoring billing purposes until such <br /> and laboratory analysis by time as the equipment is <br /> the discharger for total restored to proper working <br /> petroleum hydrocarbons order andapproved by the <br /> over the course of the dis- Oepartment of Municipal <br /> Charge. Sample collection, Utilities. <br /> frequency of sampling, 8.All costs incurred by the <br /> point of discharge,volume- Municipal Utilities Depart- <br /> tric or seasonal restric- mens for administration and <br /> tions, or other discharge treatment of the discharge <br /> conditions and limitations are to be paid for by the <br /> will be as specified in the discharger according to the <br /> Discharge Permit which rates specified for the com- <br /> shall be issued by the mercialcategory In the <br /> Director of MunicipalUtili• schedule of Wastewater <br /> ties. Service Fees in effect at the <br /> 2. Discharges shall not time of the discharge. <br /> exceed a concentration of 9.Connection fees for dis- <br /> 4.57 mg/L of Total Toxic chargers will be assessed <br /> Organics (as currently annually in accordance with <br /> listed by the Environmental the rate resolution of the <br /> Protection Agency for cate. Stockton City Council for <br /> gorical electroplatl dis- the commercial user Cate- <br /> chargers, 40 CFR 413.02 gory, amortized over a 30- <br /> (i)). Compliance with this year period. <br /> provision will be enforced 10.Any costs incurred by the <br /> by Arab samples obtained Municipal Utilities Depart- <br /> no less than once during ment for sampling and <br /> the permit term.Analytical analysis of the dischar in <br /> procedures will be in accordance with the fry's <br /> accordance with EPA rules Pretreatment Program will <br /> in Guidelines Establishin be paid for by the dis- <br /> Test vroceclures for a charger- <br /> Analysis sis o o u an s. 11. All sampling procedures. <br /> ri—nal Mule par schedules. and handling <br /> T31 71gTrah°ds 624 and provisions must be saps- = r <br /> 625. In addition, analysis factory to the Director of <br /> by the Perminee for ben- Municipal Utilities and all •i .'. _-,'1 <br /> zene. toluene. xyYlene and analyses must be con- ' ' �. 4L <br /> ethylbenzene (BTXE) will ducted by a laboratory cer- <br /> be required at frequencies III) d by the California <br /> coinciding wnh the sam- Department of Health Ser- <br /> pling and analysis for total vices for the specific analy- <br /> pelroleum hydrocarbons. sis conducted. <br /> SECTION III.EFFECTIVE DATE. <br /> - This ordinance shall become <br /> effective from and alter thirty <br /> (30) days from its final pas- <br /> Sage. <br />