136121 <br /> GENERAL NOTES <br /> ALL TANK AND LINE INSTALLATIONS SHALL BE PERFORMED AS SHOWN ON DRAWINGS <br /> M-586 AND M-588 . <br /> lO THESE PLANS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE <br /> AN EXACT REPRESENTATION OF THE FINAL PRODUCT. GENERAL CONTRACTOR <br /> TO RELOCATE, MODIFY, OR ADJUST TO PROVIDE A SYSTEM CONSISTENT WITH <br /> THE INTENT OF THE DESIGN. AS-BUILT PLANS MUST BE PREPARED AT THE <br /> COMPLETION OF THIS JOB. <br /> OINSTALL FOUR (4) 10, 000 GALLON "XERXES" DOUBLE-WALL FIBERGLASS L n C N <br /> TANKS CONNECT TO EXISTING LEAK ALARM SYSTEM. TANKS TO BE SET 48" E t 1A <br /> MINIMUM BELOW FINISH GRADE. SEE NOTE 6, DRAWING M-586 . TANKS ARE ^^ 0 ++ O <br /> 8 ' -0" NOMINAL DIAMETER AND SHALL BE INSTALLED APPROXIMATELY 2 FEET CLO. d1 C <br /> APART. SEE DRAWING M-586 FOR LENGTH AND THIS SHEET FOR LAYOUT. o ,C d r- <br /> P/L 301.60'± <br /> r CO 4) L11) <br /> 3O INSTALL A REINFORCED CONCRETE TANK SLAB. SET MANHOLE COVERS 1-1/2" ° C W o <br /> Wo <br /> ABOVE SLAB. (SLAB CROWN I ' MINIMUM CONCENTRIC) . SEE DRAWINGS o W <br /> M-586 AND M-588 . V +r 0) <br /> •H C N <br /> aQ <br /> AM/PM <br /> O FOUR INCH (4") FILL RISERS ON EACH TANK WITH OVERFILL PEEVE*IT=OPI N < C <br /> yj ON DROP TUBE AND FIVE (5) GALLON SPILL CONTAINMENT BOXES (MANHOLE <br /> a COVERS TO BE WATERTIGHT) . RISERS MUST BE GROUNDED! � � <br /> V 4) L0 <br /> �-- LEACHIN:; FACILITIES - EXISTING � p <br /> PRICE SIGN d S C NE8: O RISER FOR PHASE II VAPOR RECOVERY AND VENT CONNECTIONS WITHEXTRACTOR TEE AND BALL FLOATS (SEE TANK INSTALLATION DETAILS ON r d <br /> 1" 20DRAWING M-586) . ID <br /> C <br /> OINSTALL THREE (3) 1-1/2 HORSEPOWER SUBMERSIBLE PUMPS WITH RED L Q <br /> 0 o JACKET LEAK DETECTOR (MANHOLE COVERS TO BE WATERTIGHT) . N <br /> EXISTIN4.0 G <br /> EXISTING 7O INSTALL 2" PRODUCT LINES WITHIN 3" SECONDARY CONTAINMENT PIPING O C J <br /> TRASH (A.O. SMITH RED THREAD II OR AMERON) . SLOPE 1/4" PER FOOT BACK TO <br /> LOT LIGHT <br /> ENCLOSURE • TANKS. Y C <br /> EXISTING FREEWAY' 4 V L r <br /> EXISTING STYLE GUARD t9 <br /> L J SEPTIC TANK RAIL (TYPICAL) yr cm <br /> 8O INSTALL 3" MANIFOLDED VAPOR RECOVERY LINES SLOPE 1/41 PER FOOT TO N <br /> h REGULAR TANK, AND INSTALL 2" DIAMETER VAPOR RECOVERY MANIFOLD 1/4" Q — K <br /> h PER FOOT UP FROM REGULAR TANK TO REMAINING TANKS. 0 <br /> A/C ❑ \v r m <br /> 0 Q 9O CONNECT TO EXISTING LEAK MONITOR CONTROL BOX. 0) <br /> 2 O <br /> E: _ 10 INSTALL 2" VENT LINES, SINGLE WALL. SLOPE la"(FOOT BACK TO TANKS. CONNECT <br /> TO EXISTING 'VENT RISER. CL <br /> b �Ezistj Exlat LExlst. IExist� Exlsta <br /> EXISTING BUILDING 16 16 i I g 116M I 1 xis I 1 ,, J w'+ 11 INSTALL CONDUITS AND CONDUCTORS AND/OR PULL ROPES FOR PUMPS, <br /> c -•11- LP� II I o SAN JOAQUIN COUNTY ( MONITORING EQUIPMENT, FUTURE MONITORING EQUIPMENT, AND DISPENSERS <br /> N IStser ISteq� IStegl F berr IF berl PUBLIC HEALTH SERVICES AS SHOWN ON THIS SHEET. ALL CONDUITS LEAVING CLASS I HAZARDOUS <br /> \ j li I I ly�oeel Iq�sesl ENVIRONMENTAL HEALTH DIVISION AREAS SHALL BE SEALED PER N. E. C. AND LOCAL REQUIREMENTS. <br /> r P. 0. BOX 2004 S tOCKTON CA 95021 <br /> 4 G IIREGI UNLi IUNLVL , FILL IUNL PHOiti : ( €1 '') %.uC-3420 12 ANNULAR SPACE MONITOR (MANHOLE COVERS TO BE WATERTIGHT) . (SEE TANK <br /> ��ebni ebn (TYP.) I I "' 'y '• <br /> U. <br /> ,y 0 INSTALLATION DETAIL, DRAWING M-586) <br /> --r----- - / �y. ❑ proved ( a <br /> INSTALL 3" X 4" VAPOR CHECK VALVE AND CAP ON 4" FILL RISER SEE <br /> ARI WATER c �, 7 �� Q <0 Approve ° o 5anges: See Remarks TANKINSTALLATION DRAWING M-586) . <br /> O2I DISPENSER ai a <br /> 7 O ❑ Disapprov .. t Remarks 14 ALL APPROACHES TO BE SUFFICIENTLY BARRICADED DURING CONSTRUCTION <br /> 3 lu /1i5 J� ® Remarks___ _ TO PREVENT ANY UNAUTHORIZED TRESPASS (VEHICULAR OR PEDESTRIAN) . <br /> ° - - � cY _ — UJI <br /> — <br /> ° ° _ __ _Z _ EXACT LOCATION TO BE DETERMINED IN FIELD. <br /> R RU - INSTALL, NEW PUMP RELAYS <br /> Exist. - 8I SEE DETAIL THIS SHEET. <br /> EXISTING _J Date — g o /n/ DETAILS, <br /> TE New U�1 RS SR qlJ H 7. _ w 3 vu (n <br /> BOO I o�� UA 2 ,y Approval of the e exte to that 16 CONNECT IAT EXISTING ''.)NDER-DISPENSER CONTAIMENT. Q <br /> O � which is shown acu � -ihed <br /> does not authorize or ove a, but I7 PLACE AN ACTIVE SIPHON LINE, 2" FIBERGLASS WITHIN 3" DIAMETER <br /> EXISTING FIRE WATER ° — / d ; — ,� or deviation of requirement, of State taws or SECOND ',` CONTAINMENT PIPING, BETWEEN THE UNLEADED TANKS . SLOPE <br /> WELL, PUMP AND Ix <br /> z ° d =- ��A°'JW �f` IOCalOrdinances. 1/4" PER FOOT . REFER TO DRAWING M-588 FOR SCHEMATICS. <br /> ��� W ^ Q <br /> STORAGE TANK -- C - - +/ y; N <br /> J Exist. - UR—R - - — — - ° <br /> w D.J. O 18 PLACE INACTIVE SIPHON LINES, 2" FIBERGLASS WITHIN 3" DIAMETER W N ZI <br /> New U RS __ S yU 7 SECONDARY CONTAINMENT PIPING WITH TERMINATION END CAP FITTINGS, AS U 0 <br /> ° z 6 TYP. y Yt . SHOWN ON SHEET M-586 , BETWEEN THE TURBINE-EQUIPPED UNLEADED TANK Q <br /> � AND THE SUPER UNLEADED TANK, AND BETWEEN THE SUPER UNLEADED TANK Q Z �! <br /> a C AND THE REGULAR TANK. ALL SIPHONS TO SLOPE 1/4" PER FOOT TOWARD .�,j <br /> Z EXISTING PLANTER THE REGULAR TANK. REFER TO DRAWING M-588 FOR SCHEMATICS. a 04 Q <br /> 19 PROVIDE A STATIC GROUNDING SYSTEM AS SHOWN ON THIS SHEET. MUj IX V <br /> EXISTING P/L 250.00'± EXISTING W <br /> LOT LIGHT LOT LIGHT 20 NOT USED. W <br /> 21 PLEASE NOTE: COORDINATE INSTALLATION OF PIPING AND CONDUITS TO Z <br /> AVOID CONFLICTS WITH CANOPY COLUMN FOOTINGS. d Q <br /> 22 REMOVE EXISTING TANKS: Z N V <br /> TWO (2) 6 , 000 GALLON UNLEADED TANKS . (STEEL) �V/ >' <br /> ONE ( 1) 6, 000 GALLON REGULAR TANK. (STEEL) i i- N V } <br /> ONE ( 1) 10, 000 GALLON UNLEADED TANK. (FIBERGLASS) J Z Q ^ Q ~ <br /> ONE ( 1) 6 , 000 GALLON UNLEADED TANK (FIBERGLASS) <br /> TANKS SHALL BE REMOVED IN ACCORDANCE WITH ALL APPLICABLE STATE, ~ r O N ~ d <br /> P A T T E R S O N PASS ROAD FEDERAL, AND LOCAL REGULATIONS AND REQUIREMENTS. BACKFILL EXISTING V <br /> HOLE AND PAVE PER ARCO SPECIFICATIONS. <br /> • Z <br /> GROUNDING ULA,L 23 REMOVE ALL EXISTING PRODUCT AND VAPOR RETURN PIPING WHERE IT V c <br /> OCCURS . REMOVAL SHALL TAKE PLACE IN A MANNER WHICH DRAINS PIPING C 'O C <br /> INTO TANKS. SEAL CONNECTION TEES . NO PIPING SHALL BE ABANDONED asses 6 <br /> IN PLACE. O <br /> r Ma cai <br /> u"yonw, <br /> MAN wi24 PIPING LEAK MONITOR AT LOW POINT (TYPICAL AT EACH PIPING SUMP SEE i W <br /> APPLY SEALER COAT AS SPECIFIED TANK INSTALLATION DRAWING M-586) . H ° c1° <br /> LEGEND: <br /> IN SUPPLEMENTAL CONDITIONS O <br /> 7-,] 25 REFER TO SUPPLEMENTAL GENERAL CONDITIONS, SHEET T-2 , FOR ADDITIONAL Qi E oro Q <br /> EXISTING CONCRETE 2" PIPE WITH CONNECTION 3" (MIN.) COMPACTED DEPTH INFORMATION AND SPECIFICATIONS. L : �I_M C <br /> TYPE 'B' ASPHALTIC CONCRETE m ° C4 Ot - <br /> �� COMPACTED TO 95% OF MAX. m = `fO <br /> 26 SLURRY SEAL ENTIRE SITE AND REPAINT PARKING STRIPES UPON /M C 0 'O ' O� <br /> 5" (MIN.) COMPACTED DEPTH �` COMPLETION. Y� r c� lot 62) m <br /> ° Af JI IIC ro W 0 <br /> NEW CONCRETE - 2" PIPE NO CONNECTION) DENSITY PER ASTM D-I _ _ _ <br /> NEW A.C. PAVEMENT - NEW ELECTRICAL CONDUIT CLASS 2 AGGREGATE BASE— INSTALL INSPECTION WELL PER DWG. M-586. C W 06 Z <br /> COMPACTED TO 95% OF MAX. <br /> DENSITY PER ASTM D-1557 <br /> — -- EXISTING UNDERGROUND • FILL RISER c < �: �At�_vs \i m } <br /> .L - -- - --3 <br /> N L <br /> PRODUCT TANK 0 TURBINE (PUMP) CIA <br /> o <br /> AM ABSORBENT MATERIAL to <br /> viaivP �urTPrA ° a,ve <br /> REG or R REGULAR FH FIRE HYDRANT (CLOSEST) 1/ PUR S T ANE ,r dC V <br /> i PUMPS TO PANEL <br /> SUPER UNLEADED EITHER ON PROPERTY OR IN s� c <br /> SUP or S DIRECTION OF NEAREST ONE <br /> UNLEADED <br /> CO2 CYLINDERS FOR SOFT DRINK zo HL ON] W i R NDUIYS' F .s C •>CC4 LL <br /> UNL or U � Hr PON] wnr,iE ccrvouir ,its C a e� <br /> FG FIBERGLASS DISPENSERS o 'I Big HkO,'„ F1 Opscr <br /> STL STEEL CPO CONSUMER PACKAGED MOTOR S N C ) v <br /> t/y MAIN WATER SHUTOFF OIL (IN STORE OR BACKROOM o a o n3N co <br /> n a- <br /> MAIN ELECTRICAL PANEL STORAGE <br /> E ARC©MATIC OR OTHER EMERGENCY — �J 9n %JO C E r °o <br /> FIRE EXTINGUISHER G _ BEFORE YOU DIG No. Date Revision SYN co <br /> FE PUMP SHUTOFF SWITCHES' <br /> + FIRST AID KIT(S) OUTSIDE CALL TOLL FREE: 800-642-2444 sLDG. TYPE DESIGN BY <br /> AT SALES COUNTER ) " TANK 5 FWH O <br /> Z , UNDERGROUND SERVICE ALERT STATUS IN1./DATE <br /> NG NATURAL GAS SHUTOFF ON INSIDE WALL COMPACTED SUBGRADE OR �'�� • " LINE <br /> FOR FUEL rO �C`_ (MINIMUM ADVANCE NOTIFICATION OF 48 HOURS REQUIRED) DRAWNeY Z <br /> STRUCTURAL FILL MATERIAL ___ TANKS crvP. - si <br /> B.C.E. <br /> COMPACTED TO 95% OF MAX. REFERENCES , Inc. Engr. Review 11 REPLACE- 6M <br /> DENSITY PER ASTM D-1557. MENT m <br /> DATE <br /> Permit Submittal 5-3-90 <br /> ',JMP H :n, evrt 1. TITLE 8, ARTICLE 8, 1540, (a), 1 FAC. NO. 0 <br /> ur: DUMP i�P BE n:,, DIVISION INDUSTRIAL SAFETY, (CONSTRUCTION SAFETY ORDERS ❑ 6100 SHEET <br /> TYP. ONSITE PAVING SECTION �� ������ ���` <br /> 2. RULE 7110, CONTRACTORS LICENSE LAW Plan Permit Approve <br /> N.T.S. <br /> Bid Document ❑ TL-1 W' <br /> SINGLE LINE DIAGRAMC ❑ Cr' <br /> onstruction Release REv of <br /> tJ SCALE <br /> Stamp it 1 9 <br />