Laserfiche WebLink
136121 <br /> GENERAL NOTES <br /> ALL TANK AND LINE, INSTALLATIONS SHALL BE PERFORMED AS SHOWN ON DRAWINGS <br /> M-586 AND M-588 .' <br /> lO THESE PLANS ARE DIAGRAMMATIC IN NATURE AND ARE NOT INTENDED TO BE <br /> AN EXACT REPRESENTATION OF THE FINAL PRODUCT. GENERAL CONTRACTOR <br /> TO RELOCA'T'E., MODIFY, OR ADJUST TO PROVIDE A SYSTEM CONSISTENT WITH <br /> THE INTENT OF THE DESIGN. AS-BUILT PLANS MUST BE PREPARED AT THE <br /> COMPLETION OF THIS JOB. <br /> OTPiSTALL FOUR (4 ) 10 , 000 GALLON "XERXES" DOUBLE.-WALL FIBERGLASS C p C O <br /> TANKS CONNECT TO EXISTING LEAK ALARM SYSTEM. TANKS TO BE SET 48" M E <br /> MINIMUM BELOW FINISH GRADE. SEE NOTE 6 , DRAWING M-586 . TANKS AREw 0 C Q <br /> 8 ' -0" NOMINAL DIAMETER AND SHALL BE INSTALLED APPROXIMATELY 2 FEET y C <br /> P L 301.80'( APART. SEF: DRAWING M-586 FOR LENGTH AND THIS SHEET FOR LAYOUT. � t -C <br /> ' <br /> O INSTALL A REINFORCED E;CONCRETE TANK SLAB. SET MANHOLE COVERS 1 -1/2" O u C O <br /> IK <br /> ABOVE SLAB. (SLAB CROWN 1 ' MINIMUM CONCENTRIC) . SEE DRAWINGS Uj <br /> M-586 AND M-588 . U c 0a y <br /> EXISTING * e <br /> AMIPMSIGN- FOUR INCH �4") FILL RISERS ON EACH TANK WITH OVERF" � i>I?ti; z,n)�r_Cp) L) <br /> ui ON DROP TUBE AND FIVE (5) GALLON SPILL CONTAINMENT BOXES (MANHOLE. o <br /> - ! F H'r.+J a• ' + COVERS TO BE WATERTIGHT) . RISERS MUST BE GROUNDED! cN <br /> ,��EXISTG _j m Lf) <br /> PRICEI3GN IL RISER FOR ' PHASE II VAPOR RECOVERY AND VENT CONNECTIONS WITH Q Q <br /> SCALE: EXTRACTOR TEE AND BALL FLOATS <br /> (SEE TANK INSTALLATION DETAILS ON r <br /> 1" m 20� DRAWING M-586) O C <br /> 6� INSTALL THREE (3 ) 1-1/2 HORSEPOWER SUBMERSIBLE PUMPS WITH RED V a <br /> 0 0 JACKET LEAF DETECTOR (MANHOLE COVERS TO BE WATERTIGHT) . A 0 <br /> EXISTING 41 7O INSTALL 2" PRODUCT LINES WITHIN 3" SECONDARY CONTAINMENT PIPING 1i J <br /> EXISTING <br /> TRASH LOT LIGHT b <br /> (A. C . SMITH RED THREAD II OR AMERON) . SLOPE 1/4" PER FOOT BACK TO Q1 <br /> ENCLOS,IRE TANKS, <br /> EXISTING FREEWAY <br /> iEXISTING STYLE GUARD A/ Ln <br /> 1 11 SEPTIC TANK RAIL (TYPICAL) - \ .*i 1' li (v <br /> 9^ INSTALL 3„ MANIFOLDED VAPOR RECOVERY LINES SLOPE 1/4 PER FOOT TO - <br /> yh• REGULAR TALK, AND INSTALL 2” DIAMETER VAPOR RECOVERY MANIFOLD 1/4" Q _ K <br /> PER FOOT UP FROM REGULAR TANK TO REMAINING TANKS . M C <br /> CONNFCT TC - XI':7NG _EAK MONITOR CONTROL BOX. <br /> E _ 10 INSTALL 2" VENT LINES, SINGLE WALL. SLOPE 1/4"IFOOT BACK TO TANKS. CONNECT <br /> +i r , TO EXISTING 'FNT RISER. d <br /> IExbtl IExlat11 IExiit. (Exist. IExist4 ` 11 INSTALL CONDUITS AND CONDUCTORS AND/OR PULL ROPES FOR PUMPS, <br /> EXISTING BUfJ_1INi; g 8 16 I ISM 1 110M 1 <br /> p 1-, 1 � I�r 1 1 1 I MONITORING EQUIPMENT, FUTURE MONITORING EQUIPMENT, AND DISPENSERS <br /> ev Isteer Steer jStegll IFjberr i.1ber AS SHOWN OflI THIS SHEET. ALL CONDUITS LEAVING CLASS I HAZARDOUS <br /> i 11 1 I Igo 1 I AREAS SHALL, BE SEALED PER N. E. C. AND LOCAL, REQUIREMENTS . <br /> o G II REG ! IUNL I UNU 1111 1 4 FILL IUNL I <br /> abn abn � (TYP.). i i y 12 ANNULAR SPF CE MONITOR (MANHOLE COVERS TO BE WATERTIGHT) . (SEE TANK <br /> <V M0 INSTALLATION DETAIL, DRAWING M-586) . <br /> _ o <br /> - r - T 1g 13 INSTALL 3" � X 4" VAPOR CHECK VALVE AND CAP ON 4" FILL RISER (SEE <br /> EXIST. ; V TANK INSTALLATION DRAWING M-586) . <br /> AT ERAIR/WOz W 7 F, Q J <br /> DISPENSER U.= Z i <br /> 17 5 TYP. / 14 ALL APPROACHES TO BE SUFFICIENTLY BARRICADED DURING CONSTRUCTION Q. <br /> 0 <br /> - - ='-o / 3 �O O TO PREVENT ANY UNAUTHORIZED TRESPASS (VEHICULAR OR PEDESTRIAN) . W <br /> o - {]-` ° Z O�� <br /> 15 INSTALL NE0 PUMP RELAYS. EXACT LOCATION TO BE DETERMINED IN FIELD . <br /> Exist.-- R— RU 8 SEE DETAIL"; THIS SHEET. <br /> New—1.10RS-SR <br /> , w Q <br /> EXISTING RS SR U @! _J V/ <br /> TELEP <br /> B007-HS 8'' �7j ,o��C°'� i °� � >S 16 CONNECT T XISTINC .I^JDER-DISPEN`'ER <-ONTAIMENT. Q <br /> EXlSTIP1t� FIRE WAThR -- 17/ PLACE AN ACTIVE SIPHON LINE, 2 " FIBERGLASS WITHIN 3" DIAMETER Z 0 <br /> �� ° - - I �7 CL SECONDARY C'ONTAINMEN'T PIPING, BETWEEN THE UNLEADED TANKS . SLOPE <br /> WELL., PUMP AND 7 ° �o• <br /> STORAGE TANK-- Q Uj <br /> aW i_ 1/4" PER I �,.)'C, ih iv 'i7F�zr. ii�3 ,1 ',d€s 1 ��n zSCiVI,P1AiC� . � <br /> Exist. - UR- R �J _''o 4) y �. <br /> D.I. O 18, PLACE INACTIVE SIPHON LINES , 2" FIBERGLASS WITHIN 3" DIAMETER ZI <br /> LL <br /> New U RS ___ S U b SECONDARY CONTAINMENT PIPING WITH TERMINATION END CAP FITTINGS, AS <br /> SHOWN ON SHEET M-586 , BETWEEN THE TURBINE-EQUIPPED UNLEADED TANK 0 <br /> y - AND THE SUER UNLEADED TANK, AND BETWEEN THE SUPER UNLEADED TANK Z W4 AND THE REGULAR TANK. ALL SIPHONS TO SLOPE 1/4" PER FOOT TOWARD �I <br /> FXV -TING Ni . "`Fk THE REGULAR TANK. REFER TO DRAWT14G M-588 FOR SCHEMATICS . Q <br /> 19 PROVIDE A STATIC GROUNDING SYSTEM AS SHOWN ON THIS SHEET. W MIX U <br /> EXISTING P/L 250.00'± EXISTING 0: W <br /> LOT LIGHT LOT LIGHT <br /> 20 NOT USED. W F LL /> <br /> 21 PLEASE NOPE: COORDINATE INSTALLATION OF PIPING AND CONDUITS TO J U <br /> v � H` <br /> a <br /> woa <br /> m n AVOID CONFLICTS WITH CANOPY COLUMN FOOTINGS . a <br /> 22 REMOVE EXISTING TANKS: Z N U <br /> 05 w <br /> TWO (2 ) 6 , 000 GALLON UNLEADED TANKS . (STEEL) O } <br /> — - _ - VV <br /> ONE ( '.) 6 , 000 GALLON REGULAR TANK. (STEEL) i <br /> ONE ( ]-) 10 , 000 GALLON UNLEADED TANK. (FIBERGLASS) LU Z 1-" 44 <br /> ~ <br /> roou. wmi ONE (1.) 6 , 000 GALLON UNLEADED TANK (FIBERGLASS) <br /> TANKS SHALL BE REMOVED IN ACCORDANCE WITH ALI., APPLICABLE. STATE, L <br /> P A T T E R S O N PASS ROAD FEDERAL, AND LOCAL REGULATIONS AND REQUIREMENTS . BACKFILL EXISTING J <br /> HOLE AND PAVE PER ARCO SPECIFICATIONS . <br /> ■ Z <br /> 23, REMOVE ALL EXISTING PRODUCT AND VAPOR RETURN PIPING WHERE IT V o <br /> OCCURS. REMOVAL SHALL TAKE PLACE IN A MANNER WHICH DRAINS PIPING ro c <br /> INTO TANKS . SEAL CONNECTION TEES. NO PIPING SHALL BE ABANDONED 6 <br /> 0 <br /> IN PLACE. 0 <br /> M m V L) <br /> 24 PIPING LEAF MONITOR AT LOW POINT (TYPICAL AT EACH PIPING SUMP SEEiz <br /> " <br /> APPLY SEALER COAT AS SPECIFIED- - TANK INSTALLATION DRAWING M-586) Ce <br /> LEGEND: IN SUPPLEMENTAL_ CONDITIONS tm <br /> REFER TO SUPPLEMENTAL GENERAL CONDITIONS, SHEET T-2 , FOR ADDITIONAL C W we <br /> EXISTING CONCRE=TE 2" PIPE WITH CONNECTIONT ( E COMPACTED DEPTH <br /> 71 TYPE B' ASPHALTIC CONCRETE INFORMATION AND SPECIFICATIONS . C E �9=� <br /> - - —_ COMPACTED TO 95% OF MAX. <br /> NEW <br /> —_ ` f <br /> NEW CONCRETE 2" PIPE `,40 CONNECTiUN DENSITY PER ASTM D-1557 26V' SLUR} f I'Al F.NIIRF SITE AND REPAINT PARKING STRIPES UPON � o0)ii <br /> COMFLETIJN ? � 9 <br /> - ---- 5 (MIN.) COMPACTED DEPTH C LU <br /> NEW A.C. PAVEMENT NEA E'1_ECTRICAL CONDUIT CLASS 2 AGGREGATE BASE__ 27 S1 AL.L INSPF`'TION WELL PER DWG, M-586. <br /> DEENSICOMPTYTPEERED TASTM/D OF 57 <br /> C <br /> - - EXISTING UNDERGROUND • FILL RISER <br /> I- -- --- -- I PRODUCT TANK 0 TURBINE !PUMP) N <br /> L N <br /> AM ABSORBENT MATERIAL <br /> REG or R REGULAR FH FIRE HYDRANT (CLOSEST) Jill'; To I'AJF: 3- �9 �/ - 60) <br /> SUP or S SUPER UNLEADED EITHER ON PROPERTY OR IN - A�Jfv �t y c N <br /> y <br /> DIRECTION OF NEAREST ONE Y <br /> UNL or U CO2 CYLINDERS FOR SOFT DRINK C •« <br /> UNLEADED <br /> ti- +� �� v. C -9 CW <br /> FG FIBERGLASS DISPENSERS o o MAY 1 1199s7 <br /> STL STEEL CONSUMER PACKAGED MOTOR r <br /> C n o N3N <br /> W MAIN WATER SHUTOFF CPG OIL (IN STORE OR BACKROOM f <br /> MAIN ELECTRICAL PANEL STORAGE I I ao- I�� �NVIRC7NMENTALHEALTF ° <br /> E (i ARC®MAI'IC OR OTHER EMERGENCY PERMIT/SERVICES O a E Nco <br /> FE FIRE EXTINGUISHER PUMP SHUTOFF SWITCHES, <br /> BEFORE YOU DIG m V _j _ �Y" <br /> + FIRST AID KIT(S) OUTSIDE No. Date tiavts(on O <br /> AT SALES COUNTER CALL TOLL FREE: 800-642-2444 � BLDG. TYPE DESIGN BY <br /> NG NATURAL GAS SHUTOFF AT INSIDE WALL "UNDERGROUND SERVICE ALERT" STATUS INIJDATE TANK II FWH �6 <br /> COMPACTED SUBGRADE OR (MINIMUM ADVANCE NOTIFICATION OF 48 HOURS REQUIRED) LINE <br /> L <br /> STRUCTURAL FILL MATERIA _ _ DRAWN er Z <br /> COMPACTED TO 95% OF MAX. REFERENCES B.C.E., Inc. Engr. Review ❑ REPLACE- gM <br /> DENSITY PER ASTM D- 1557. MENT DATE <br /> 1. TITLE 8, ARTICLE 8, 1540, (a), 1 Permit Submittal 11 <br /> DIVISION INDUSTRIAL SAFETY, CONSTRUCTION SAFETY ORDERSFAC. NO, 5-3-90111) <br /> TYP. ONSITE PAVING SECTION 2. RULE 7110, CONTRACTORS LICENSE LAW Plan/Permit Approval ❑ 6100 SHEET <br /> N.T.S. Bid Document ❑ TL-1 W <br /> SINGLE LINE DIAGRAM Construction Release ❑ of V <br /> Stamp REV. <br /> !J i! � <br />