Specification <br /> GUIDE SPECIFICATIONS <br /> DOUBLE WALL <br /> FIBERGLASS REINFORCED PLASTIC (FRP), <br /> UNDERGROUND STORAGE TANKS <br /> SHORT FORM: <br /> The contractor shall provide Double Wall Fiberglass Reinforced Plastic(FRP)U.L.labeled underground storage tanks as shown on the drawings. <br /> Sizes and fittings shall be as shown.The tanks shall be Century-Cast Tanks as manufactured by XERXES CORPORATION. <br /> Tanks shall be tested and installed with pea gravel or crushed stone as specified in the current installation instructions provided with the tank. <br /> LONG FORM: Section 15177-1 3. Tanks shall be capable of storing gasoline or gasohol(10%ethanol and <br /> 90%gasoline mixture),jet fuel,diesel fuel,AV gas,potable water at <br /> Part I General ambient underground temperature or fuel oil at temperatures not to <br /> exceed 150°F. <br /> 1.01 Related Work Specified in Other Sections C. Each tank shall be equipped with two 22"I.D.manways.Each steel manway <br /> A. Liquid Level Gauges:Section 15174 cover shall have three 4"NPT fittings welded in place. <br /> B. Plastic Pipe:Section 15064 D. Materials: <br /> C. Anchor Bolts:Section 05501 <br /> D. Cast-in-Place Concrete:Section 03300 1. Tanks(Primary and Secondary)shall be manufactured with 100% <br /> isophthalic polyester resin and glass fiber reinforcement with no sand <br /> 1.02 Quality Assurance fillers. <br /> A. Acceptable Manufacturer:XERXES CORPORATION E. Annular Space <br /> B. Governing Standards;primary tank: 1. Tank shall have a space between the primary and secondary shell walls <br /> 1. ASTM standard document number D4021-81. to allow for the free flow and containment of all leaked product from the <br /> 2. Underwriters Laboratories,Inc.(U.L.)File MH 9061 for storage of flam- primary tank.Space also allows the insertion of a monitoring device <br /> mable liquids.A U.L.certification plate shall be attached to each tank. through a monitoring fitting. <br /> 3. National Fire Protection Association(NFPA30)Flammable and F. Tank Dimensions(Refer to Xerxes literature on gallonage.) <br /> Combustible Liquids Code and(NFPA31)Standard for Installation of Oil 1. Tank shall have nominal capacity of gallons. <br /> Burning Equipment. 2. Tank shall have nominal outside diameter feet. <br /> 4. National Sanitation Foundation,Standard 14. 3. Tank shall have approximate overall length of feet. <br /> 5. Military Specifications No.MIL-T-52777. 2.02 Accessories <br /> C. Governing Standards;secondary tank: A. Anchor Straps-Provide FRP anchor straps as manufactured by tank <br /> 1. Underwriters Laboratories,Inc.(U.L.)File MH 9061 for storage of flam- manufacturer.Number and location of straps shall be specified in current <br /> mable liquids.A U.L.certification plate shall be attached to each tank. installation instructions of tank manufacturer. <br /> 2. National Fire Protection Association(NFPA30)Flammable and B. Manways <br /> Combustible Liquids Code and(NFPA31)Standard for Installation of Oil 1. All manways to be flanged and 22"I.D.complete with U.L.listed <br /> Burning Equipment. gaskets,bolts and covers.(30"I.D.manway is also available.) <br /> 3. Factory Mutual Systems approval IM7AOAF. 2. Location as shown on drawings. <br /> 1.03 Submittals 3. Manway extension tubes shall be FRP and 24"long for manways shown <br /> A. Shop Drawings:Contractor shall submit copies of shop draw- on drawings. <br /> ings for each tank.Drawings shall show locations of all fittings,accessories, 4. Each steel manway cover shall have three-4"NPT fittings welded in <br /> and critical dimensions. place. <br /> B. Catalog Data:Contractor shall submit copies of manufacturer's liter- C. Fill Tubes <br /> ature to include copies of manufacturer's current installation Y Y 1. Tubes shall be FRP and factor installed b manufacturer. <br /> instructions. <br /> 2.. Location as shown on drawing. <br /> 3. Tubes shall be 4"diameter with 6"steel fitting and a 6"x 4"double <br /> tapped reducer bushing. <br /> PART I i Products D. Gauge Plates-Shall be installed at location shown on drawing. <br /> 2.01 Double Wall Fiberglass Reinforced Plastic(FRP)Underground Storage E. Heating Coils <br /> Tanks with a Primary(internal)tank and a Secondary(external)tank. 1. Heating Coils shall be installed in a separate 22"manway and shall be <br /> A. Loading Conditions-Tank shall meet the following design criteria: standard items supplied by tank manufacturer. <br /> 1. Internal load:Primary and Secondary tanks shall withstand 5 psi air 2. Location as shown on drawings. <br /> pressure test with 5 to 1 safety factor.Contractor shall individually test F. NPT Threaded Fittings <br /> tanks prior to installation as this is to test for leakage.Maximum test <br /> pressure is 5 psi. 1. All threaded fittings shall be a material of construction consistent with <br /> 2. Vacuum Test:Every tank shall be mercury vacuum tested by the tank the requirements of U.L.label. <br /> manufacturer to assure structural integrity.Primary tank shall be tested 2. All standard thread fittings shall be half couplings and shall be 4"in <br /> to 11.5 inches and secondary tank tested to 9.5 inches mercury diameter.Reducers are to be used for smaller sizes where shown and <br /> vacuum. provided by contractor. <br /> 3. Surface Loads:Tank shall withstand surface H-20 axle loads when 3. Sizes Standard Other Sizes <br /> properly installed according to current manufacturer's installation Fill 4" <br /> instructions. Gauge 4" <br /> 4. External hydrostatic pressure:Buried in ground with T of overburden Inlet 4" <br /> over the top of the tank,the hole fully flooded and a safety factor of 7:1 Outlet 4" <br /> against general buckling. Vent 4" <br /> 5. Tanks shall support accessory equipment such as heating coils,drop 4. Suction Line-Shall be installed by contractor on site.Pipes shall termi- <br /> tubes,submersible pumps,ladders when installed according to tank nate a minimum of 4"from bottom of tank. <br /> manufacturer's recommendations and limitations. 5. Return line shall be installed by contractor. <br /> B. Product Storage: G. Monitor Fittings <br /> 1. Tanks shall be capable of storing petroleum with specific gravity up to 1. Tank shall have test monitor fittings consisting of a 4"NPT fitting on the <br /> 1.1. secondary tank. <br /> 2. Both primary and secondary tanks shall be individually vented to atmo- 2. Tank shall have two monitor fittings,one near each end of the tank. <br /> spheric pressure.The tanks are not designed as pressure vessels. (Tanks of less than 3000-gallon capacity have only one monitor fitting.) <br /> TURY FIBERGLASS <br /> XERXES-,, I HORN PROCESSFIBERGLASS <br /> ENT'" <br /> C.F.123/DWT 7/87 CORPORATION <br />