Laserfiche WebLink
i <br /> jj Power Consumption: 1W per module Electrical Connection: '/z "-14 NPT with PVC- <br /> Supply Voltage: 24 VDC from I.S. power supply insulated 18 AWG leads <br /> FM Approved, �L Listed 48R0 Pressure: <br /> Setpoint: JT-2 Positive Pressure Leak Sensor, <br /> 7.4 Power Supply I.S. (Intrinsically Safe) .5 psig; JT-2V Vacuum Leak Sensor, .5 inches of <br /> Power Input: 115 VAC mercury <br /> Connection: '/,"-18 NPT <br /> Output Voltage: 24 VDC Adjustment: '/e" Allen wrench through port <br /> <> <br /> M Approved, UL Listed 48RO Temperature Range: —400 to 180°F (-400 to <br /> 7.5 Tank Leak Sensor, Model LS-3 82°C) <br /> Housing: 304 stainless steel lJL Listed 48RO <br /> Mounting: '/z" NPT male thread or extension CSA Approved: File 34146 <br /> cable <br /> Switch: <br /> Type: Single pole, single throw N.C. <br /> Rating: 10 VA 8.0 INTRINSICALLY SAFE <br /> Float material: Buna-N INTERFACE SYSTEM <br /> Pressure: 50 psi maximum <br /> Leads: 20 AWG 8.1 Applications <br /> UL Listed 48RO The Series X53BA-2000 Barriers are designed to <br /> handle the following functions associated with <br /> 7.6 Tank Leak Sensor, Model LS-7 intrinsically safe annunciators and logic systems. <br /> For steel and fiberglass double-wall tanks. A method of accepting intrinsically safe input <br /> Housing Material: PVC (Geon 87241) contact signals from the hazardous area via an <br /> Liquid SpG: ,70 minimum approved barrier to provide output contacts that <br /> can be used for operating general-purpose <br /> !l Switch: annunciators or logic systems. <br /> Type: Single pole, single throw N.C. <br />_ Rating: 10 VA 8.2 Mechanical Features <br /> Leads: 20 AWG Input and output terminals are physically <br /> �L Listed 48RO separated. <br /> 7.7 Hydrostatic Leak Sensor, The input terminal compartment has conduit <br /> knockouts, as do the output terminal <br /> Model LS-10 or LS-20 compartments and power wiring input. <br /> i Reservoir: No passageways exist between the two compart- <br /> Volume: ments, so it is impossible to inadvertently <br /> LS-10, two gallons (7.57 liters) intermix the input and output wiring. <br /> LS-20, four gallons (15.14 liters) <br /> Material: Polyethylene plastic 8.3 Special Installation Instructions <br /> i Switch: Model LS-3 N.O. and LS-30 Equipment and associated wiring approved as <br /> Type: LS-3 N.O., single pole, single throw; LS-30, intrinsically safe may be installed in any <br /> DPDT hazardous location for which it is approved. The <br /> Rating: 10 VA provisions of Articles 500-517 of the National <br /> Float material: Buna-N Electrical Code need not apply to such <br /> Pressure: 50 psi maximum installations. <br /> Leads: 20 AWG <br /> As the intrinsically safe portion of the system is <br /> 11L Listed 48RO made up of the field contacts and associated <br /> wiring, all field contact wiring is to be run in <br /> 7.8 Tank Leak Sensor, Model JT-2 conduit reserved for the exclusive use of this <br /> Housing: Stainless steel, explosion proof, field contact wiring. <br /> hermetically sealed, NEMA Types 7 and 9 The field contact wiring for any particular field <br /> Classification: contact is to be of such size that the total loop <br /> Class 1: Groups A, B, C and D resistance is less than 1,000 ohms. <br /> Class 2: Groups E, F and G The system is to be grounded at the input <br /> Switch: voltage terminals. The ground connection shall <br /> Type: Single pole, double throw N.O. be such that the resistance to ground shall be <br /> (shelf condition) less than 1.0 ohm. <br /> Rating: 10 VA <br /> 5 <br />