My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000459
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
2908
>
3500 - Local Oversight Program
>
PR0544111
>
ARCHIVED REPORTS XR0000459
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 3:35:45 PM
Creation date
2/7/2019 2:16:35 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000459
RECORD_ID
PR0544111
PE
3528
FACILITY_ID
FA0003625
FACILITY_NAME
ARCO STATION #83560*
STREET_NUMBER
2908
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09763032
CURRENT_STATUS
02
SITE_LOCATION
2908 W BENJAMIN HOLT DR
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
107
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr Kyle Christie <br /> December 11, 1995 <br /> Page 4 <br /> grab samples are taken at the system influent and effluent to ensure that the conditions of the <br /> Authonty-to-Construct are met <br /> Operating Conditions This Quarter During the third quarter of 1995, the GWES operated <br /> 100 percent of the time at an average flow rate of 2 3 gpm, extracting and discharging a total <br /> of 333,215 gallons of groundwater The total amount of BTEX and TPH-G in the extracted <br /> groundwater is shown in Table 4 The analytical results are included in Exhibit C The 4 <br /> quantity of BTEX and TPH-G discharged to the sewer is well within the limits stated in the <br /> permit <br /> The SVET system operated 100 percent of the time during the third quarter of 1995. The <br /> system is currently configured to extract vapor from wells V-3 and V-12 which are located on <br /> the northeast portion of the site Vacuum influence data were collected in September and are <br /> presented on Figure 3 The data suggest that there is at least 0 10 inches of water column <br /> vacuum influence in the area where a product release occurred in the second quarter of 1995 <br /> During the third quarter, the system extracted and treated approximately 2257 pounds <br /> (364 gallons) of TPH-G and 43 1 pounds (5 9 gallons) of benzene, an increase of 60 4 percent <br /> over the last quarter Table 5 presents a summary of the SVET system data and Table 6 <br /> summarizes the status of the individual soil vapor extraction and air sparging wells <br /> iThe AS system did not operate from August 30 to September S, 1995 for system maintenance <br /> During operation, the AS system functions within design parameters and delivers an average <br /> of 3 4 cubic feet per minute (cfm) of sparge air into individual air sparging wells Air <br /> sparging well data is presented in Table 6 As required by San Joaquin County, dissolved <br /> oxygen readings are being collected for selected monitoring wells Dissolved oxygen <br /> readings are presented in Table 7. Monitonng of dissolved oxygen levels for selected <br /> monitoring wells will be conducted on a monthly basis <br /> During the second quarter of 1995, a product line leak was discovered on the northern pump <br /> island At the time of discovery, approximately 3 feet of free product thickness was <br /> measured Upon discovery, ARCO immediately began removing free product from well E-10 <br /> using a disposable bailer Free product is removed once a week To date approximately 30 <br /> gallons of free product have been removed from well E-10, and the free product thickness has <br /> decreased to approximately 13 feet The removed product is stored in a 55-gallon drum <br /> contained in a plastic overpack drum which is secured inside the SVETS compound After <br /> the free product thickness has been sufficiently reduced, a passive free product skimmer will <br /> be installed in this well <br /> • Use or disclosure of data continued on this sheet is subject to the restriction specified at the beginning of this <br /> document <br /> 2060\REPORTWRD95QTR DOC <br />
The URL can be used to link to this page
Your browser does not support the video tag.