Laserfiche WebLink
SEQUOIA ANALYTICAL <br /> 819 Striker Avenue Suite 8 • Sacramento CA 95834 <br /> (916) 921 9600 • FAX (9161 921 0100 <br /> Brown & Caldweil Client Prosect ID Arco 2133-94-5 Stoclxton Sampled Mar 15 1994 <br /> P 0 Bax 13449 Sample Matrix Nater Received Mar 16 1994 <br /> Sacramento CA 95813-3449 Analysis Method FFA 5030/8015/8020 Reported Mar 30 1994 <br /> Attention Mindv Wright First Samole # -103-0688 <br /> TOTAL PURGEABLE PETROLEUM HYDROCARBONS with BTEX DISTINCTION <br /> Reporting Sample <br /> Analyte Limit I D <br /> ,ug/L 403-0688 <br /> Tank <br /> Purgeable <br /> Hydrocarbons 50 830 <br /> Benzene 050 44 <br /> Toluene 050 24 <br /> Ethyl Benzene 050 26 <br />• Total Xylenes 050 120 <br /> Chromatogram Pattern Gasoline <br /> C6-C12 <br /> Duality Control Data <br /> Report Limit Multiplication Factor 10 <br /> Date Analyzed 3/22/94 <br /> Instrument Identification HP-2 <br /> Surrogate Recovery, % 122 <br /> (QC Limits = 70-130%) <br /> Purgeable Hydrocarbons are quantitated against a fresh gasoline standard <br /> Analytes reported as N 0 were not detected above the stated reporting limit <br /> SEQUOIA ANALYTICAL <br /> �AaLtee <br /> C <br /> Craig C <br /> Project Manager <br /> 4030688 BRS <11> <br />