Laserfiche WebLink
r Y' 985 larvas Drive <br /> Sequoia Morgan H11 CA9537 <br /> D37 <br /> (408)776-9600 <br /> Analytical FAX(408)782 6308 <br /> www sequoialabs corn <br /> SCCOr-Rancho Cordova(ARCO) Project ARCO 42133, Stockton,CA MPCO246 <br /> 3017 Kilgore Rd Suite 100 Project Number Arco#2133, Stockton,CA Reported <br /> Rancho Cordova CA,95670 Project Manager Brian Carey 04/11/06 09 55 <br /> ANALYTICAL REPORT FOR SAMPLES <br /> Sample ID Laboratory ID Matrix Date Sampled Date Received <br /> AS-8-S-10-060223 MPCO246-01 Soil 02/23/06 09 27 03/04/06 08 00 <br /> AS-8-S-12 5-060223 MPCO246-02 Soil 02/23/06 09 22 03/04/06 08 00 <br /> AS-8-S-15-060223 MPCO246-03 Soil 02/23/06 09 20 03/04/06 08 00 <br /> AS-8-S-20-060223 MPCO246-04 Soil 02/23/06 09 50 03/04/06 08 00 <br /> AS-8-S-25-060223 MPCO246-05 Soil 02/23/06 09 45 03/04/06 08 00 <br /> AS-8-S-37 5-060223 MPCO246-06 Soil 02/23/06 12 00 03/04/06 08 00 <br /> AS-8-S-45-060223 MPCO246-07 Soil 02/23/06 12 20 03/04/06 08 00 <br /> AS-8-S-47-060223 MPCO246-08 Soil 02/23/06 12 59 03/04/06 08 00 <br /> AS-9-S-9-060224 MPCO246-09 Soil 02/24/06 08 23 03/04/06 08 00 <br /> AS-9-S-15-060224 MPCO246-10 Sol] 02/24/06 08 21 03/04/06 08 00 <br /> AS-9-S-20-060224 MPCO246-11 Soil 02/24/06 10 21 03/04/06 08 00 <br /> AS-9-S-26-060224 MPCO246-12 Sol] 02/24/06 10 15 03/04/06 08 00 <br /> 10-9-S-34-060224 MPCO246-13 Sol] 02/24/06 10 11 03/04/06 08 00 <br /> AS-9-S-43 5-060224 MPCO246-14 Soil 02/24/06 12 10 03/04/06 08 00 <br /> AS-9-S-53 5-060224 MPCO246-15 Soil 02/24/06 13 38 03/04/06 08 00 <br /> The carbon range for the TPH-GAO has been changed from C6-C10 to C4-C12 The carbon range for TPH-DAO has been changed <br /> from C 10-C28 to C 10-C36 EPA 8015B has been modified to better meet the requirements of California regulatory agencies <br /> These samples were received with no custody seals <br /> Note Samples were received with less than one half of the holding time remaining for all samples Client was notified that there was <br /> a high probability that the laboratory would not be able to analyze the samples within holding time due to the limited time remammg <br /> 8260E -These samples were received with insufficient time to meet the 48 hour hold time for sample preparation dictated by GCLN <br /> protocol <br /> �quola Analytical -Morgan Hill The results in this report apply to the samples analysed in accordance with the chain of <br /> custody document Unless otherwise stated,results are reported on a wet weight bases <br /> This analytical report must be reproduced in its entirely <br /> Page 2 of 28 <br />