My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS PR0544112
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BENJAMIN HOLT
>
3128
>
3500 - Local Oversight Program
>
PR0544112
>
ARCHIVED REPORTS PR0544112
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/7/2019 4:43:00 PM
Creation date
2/7/2019 3:33:41 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
PR0544112
RECORD_ID
PR0544112
PE
3528
FACILITY_ID
FA0005145
FACILITY_NAME
EXXON COMPANY USA
STREET_NUMBER
3128
Direction
W
STREET_NAME
BENJAMIN HOLT
STREET_TYPE
DR
City
STOCKTON
Zip
95207
APN
09523002
CURRENT_STATUS
02
SITE_LOCATION
3128 W BENJAMIN HOLT DR
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
942-038S5 burrLr.t�c... avn. ,n�..,... ....:..:_. <br /> EXXON CONTRACTUAL SiAFM REQUIREMENTS <br /> FOR RETAIL FACILITIES <br /> INTRODUCTION <br /> These rules and procedures are incorporated u s pact of Exxon's Construction Centro[lir work Order. and Continuing Service onhen Area <br /> Maintenance Agreements or Area Service Agreemottts,and must be comptaed with by each Contractor,his subcontractors,and employees,when w kin$ <br /> In Exxon facilities. The primary purpose of these rules is to prevent accidents which MY result in personal injury or property damage. <br /> It is intportsnt to recognize that the rules an9 procedures contained herein cannot cover all sitwtions. arsd they do net relieve she Cantraetar of his <br /> .responsibility to use good judgrnent at all times and to observe additional prtcautians that may be [seeded• <br /> GENERAL <br /> All work is to be dans in accord►rtee with any applicable local municipal.state or federal laws,rules or regulations,including the Occupational Safety and <br /> Health Act and Exxon's standards. <br /> When the station is to mmaia in operation during the performance of the contracted work,the Contractor should meet with the tsadao Oneralot and <br /> Fxxor'e representative to coordinate activities and insure the safety procedures for the particular location an cleariy understood by 111 personnel.If it <br /> develops that it is not possible or practical for an$neon represenuttive to treat with the Contractor and stA1ivtt upcfator,safety prtscedums Cor the pnrticulw <br /> aite and circumstance based on the fallowing guidelines aro to be agreed upon by the operator and the Contractor.The Contractor crust recagnite a shared <br /> responsibility for safety on the site. if the station is not in operation,the Contractor is to establish a clear undcrsutrding of safety procedures for the <br /> ' panicular sits with the Exxon representative and ha will be responsible for all safety procedures relativs to the conimet work unless otherwise dirowed by <br /> the Exxon representative or local authorized officials. ante of intoxicants or <br /> It Is rv%1JlSJcv tv G.=.,a«rl:,+ivts. friaries,slasholio bevsruget or ata:+orate n"tri Fermi pmnrRy, Pertcln>; dgf Oki# IfE�1W <br /> naacotics are not permitted on the site. <br /> Salaking is prohibited treat those areas spectf ically marked"No Smoking."If questions arise as to smoking in unmarked areas,it shall be restricted to the <br /> station office only. Discarded matches that have not been used should be placed in trach receptacles. It is the responsibility of the Contractor to enforce <br /> these regulations upon those people under his sapervisi0n. <br /> When working in areas where flammable vapors may be present,particular care must be exorcised with tools t.�a=May be sources of ignition.Suet areas <br /> maybe used if done so In a taanner to avoid striking spark$.Steel spikes,climbers or foot wear with metal appurtenances on the.soles are prohibited in areas <br /> where flammable vapors may be present. <br /> The Contractor shall keep the work site a.d adjoining premises. driveways,walks and $[rests clear of rubbish. Thr, cleat he shall dispose a 811 <br /> rubbish,waste srtd excess material Ina manner satisfactory to Exton.ldpon cnmptetion of work,the Contactor shall broom clean the canserucdon site and <br /> leuve all fixtures and equipment in a first class.sieaa, usable condition. <br /> TRAFFIC AND VEHICLE ItEGUi:.AT1ONS <br /> Contractor'[vehicles and mobile equipmentsbot ase puked sa as to block fire hydrants,etlsergency equipment,buRdingcxits,walkways.etc.Where <br /> during constuctioa or improvement,work shalt be costed an with[east possible interference to <br /> its existing cervica station must remain in operation <br /> business. <br /> on property sh►fl be immediately reported to etre station operator and the Exxon representative.When <br /> /lay accident,spilt or incident that occurs Ott Exx <br /> tate station is inoperative,any such incident shall be reported to the Exxon representative.The appropriate iota{authorities thea!tx notified according t0 <br /> Fecal laws. <br /> EXCAVATION. DRILLINO OR PILE DRIVING <br /> Before commencing with excavation in an Exxon facility and before starting any drilling,pile driving or driviag of posts.ground rods,otc..er any Other <br /> ground breaksSe.the Contractor must consult with slid obtain the specific authorization Of the Exon representative. <br /> Contractor shall properly barricade al!open holes,trenches and obstacles.Easements and access ways shall not be corn up withoutauth*"&1ivn.if hales <br /> are required to be left open ducting not[-working hours,they shill be adequately decked over Or barricaded and sufficiently lighted at night with exptosio" <br /> proof equipment. Flame tyle lighting will not be permitted. <br /> When underground storage tanks must be tilled with gasoline immediately upon inslallalivn,"Nu S+itoking"signs are to be displayed,and tanks must be <br /> equipped with vents that diSCharge at least 12 feet above the ground.No source of ignition,such as disconnccting and switching of etacthcal cquiptrttnt, <br /> open flames.engine exhausts. eco..shall be permitted within 20 feet of tank excavation. <br /> Irany gasoline is being stored on the work site.a minimum atone 2S lb.dry chemical fire 9xtinguisher must be accessible within 100 feet Of the work site. <br /> CATHODIC PROTECTION <br /> Since cathodic protection is not installed In every service Matic".the following procedures apply Only to chose Contractors working in Exxon facilities <br /> that have cathodic protection systems. <br /> The Contractor shall obtain a copy ofthe cathodic protection wbuitt plan fartha specific station.Contractor shall review the pian and consult the ocean <br /> Canter personnel before commencing work. ' <br /> When the work involves the following,the Contractor shall request that the stativ,+i..a�tager disengage 0a eathedie protection syctem: <br /> I. All work on underground equipment(tanks.piping,lifts.conduit). <br /> 2. All work on abOve-SfOund POMIOns Of cathodieaJly protected itruclurct. <br /> !.The diseornection or reassembling of cathodic protection esble, <br /> A. Ground breakage in Close proximity to cathodic protection cable. <br /> precautions must be taken when a Contractor must break ground or work on any aboveground portions of cathodically protected structures so that the <br /> -" cat;todie protection system is left undisturbed.Electrical shock and spark hazards exist if any connecting cables or main pipe lines are disconnected while <br /> the system is in operation. <br /> Contractor truer immediately advise the taxon "from the dome ed cable until the station manager disengages the cathodic protbe 4U%, nicked. pued or disconnected by ection onrsystem• <br /> f'nmrorrnr tha1T tern his parionnil gYtd OilQUI?iIF away S <br /> Contractor shall not resume work until instructed by Exxon Center personnel. <br />
The URL can be used to link to this page
Your browser does not support the video tag.