December 28, 1992 Working To Restore Nature <br /> Former Exxon Station No 7-3330, Stockton, California <br /> TPHg and BTEX were below detection limits in water sampled from wells MW-3, MW-4,'� <br /> and MW-5 These results are shown on Table 1 <br /> SUMMARY AND RECOMMENDATIONS / <br /> Gasoline hydrocarbons were detected in the sample from well MW-6✓but not in samples <br /> from the other wells The direction of ground-water flow during this sampling event is <br /> consistent with that previously evaluated The next sampling event has been scheduled for <br /> February 1992 <br /> We recommend a copy of this report be forwarded to Mr Mike Infurna of the San Joaquin <br /> County Public Health Service, Environmental Health Division P O Box 2009, Stockton, <br /> California 95201 and Ms Elizabeth Thayer of the California Regional Water Quality <br /> Control Board, Central Valley Region, 3443 Routier Road, Sacramento, California 95827- <br /> 3098 <br /> Please call if you have any questions regarding this protect <br /> Sincerely, <br /> RESNA Industries <br /> G egg Altiman <br /> No 4313 <br /> Pr ,sect Geologist <br /> � W�" w" <br /> Of CALIE4��`P <br /> ohn Bailey Bobbitt <br /> R G 4313 <br /> Attachments Table 1, Ground-Water Monitoring Data <br /> Plate 1, Site Vicinity Map <br /> Plate 2, Generalized Site Plan <br /> Plate 3, Potentiometric Surface Map <br /> Field Methods <br /> Chain of Custody Record <br /> Laboratory Analysis Reports <br /> 32020-1 <br /> 1209mgue 3 <br />