Jun 09 08 11:06a p.3 <br /> Page 2 of 4- CARPOL GP-6515 <br /> SKID: Wash thoroughly with soap and water. <br /> INHALATION: Remove victim to fresh air. <br /> INGESTION: If victim is conscious, give 1 to 2 glasses of water for dilution. Do not induce vomiting <br /> unless directed to do so by medical personnel. <br /> SECTION 5—FIRE AND EXPLOSION DATA <br /> FLASH POINT: >200 OF(PMCC) <br /> LFL: Not determined. <br /> UFL: Not determined. <br /> HAZARDOUS COMBUSTION MATERIALS: Oxides of carbon. <br /> EXTINGUISHING MEDIA: Dry chemical, foam, carbon dioxide, water fog or fine spray. Do not use <br /> direct water spray. <br /> SPECIAL FIREFIGHTING PROCEDURES: Responding personnel must wear positive-pressure, self- <br /> contained breathing apparatus(SCBA) and protective firefighting clothing. <br /> SECTION 6—ACCIDENTAL RELEASE MEASURES <br /> CONTAINMENTICLEANUP: Stop leak, dam spill, and transfer liquid into a suitable container. Collect <br /> residue with absorbent and transfer into a suitable container for proper disposal. <br /> SECTION 7—HANDLING AND STORAGE <br /> HANDLING: Keep containers tightly closed when not in use. Do not eat, drink, or smoke in working <br /> area. <br /> STORAGE: Store materials in a cool, dry place. <br /> SECTION 8—PERSONAL PROTECTION 1 EXPOSURE CONTROLS <br /> RESPIRATORY PROTECTION: None required under normal use. <br /> EYE PROTECTION: Safety glasses with side shields or chemical goggles, if there is a possibility of <br /> splashing. <br /> SKIN PROTECTION: Butyl, nitrile, or latex rubber gloves. <br /> ENGINEERING CONTROLS: General ventilation. <br /> ADDITIONAL PROTECTION: Eyewash station and safety shower. <br />