My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0004928
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
85
>
3500 - Local Oversight Program
>
PR0544124
>
ARCHIVED REPORTS XR0004928
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/8/2019 3:41:04 PM
Creation date
2/8/2019 3:10:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0004928
RECORD_ID
PR0544124
PE
3500
FACILITY_ID
FA0012144
FACILITY_NAME
ARCO STATION #6080
STREET_NUMBER
85
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
LATHROP
Zip
95330
APN
19627010
CURRENT_STATUS
02
SITE_LOCATION
85 LOUISE AVE
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
TMorelli
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
14
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Date December 10,2002 <br /> Quarter: 3rd Quarter,2002 <br /> • <br /> APPENDIX A <br /> FIELD AND LABORATORY PROCEDURES <br /> Sampling Procedures <br /> Sampling equipment is thoroughly cleaned prior to each sample The sampling procedure for each well includes <br /> measuring the water level and checking for the presence of separate-phase hydrocarbons (SPH), using either an <br /> electronic indicator and a clear TeflonO bailer or an oil-water interface probe If the measured water level in the well <br /> is below the top of casing elevation,the well may be sampled without purging For non-purge wells,one set of water <br /> quality paramenters are collected and the well is sampled with a disposable bailer Wells not containing SPH that do <br /> not qualify as non-purge wells are purged of approximately three casing volumes of water (or to dryness) using a <br /> submersible pump, centrifugal pump, gas displacement pump, or bailer The equipment and purging methods used <br /> for the current sampling event are noted on the attached field data sheets During purging, temperature, pH, <br /> electrical conductivity, and dissolved oxygen are morutored in order to document that these parameters are stable <br /> prior to collecting samples After purging,water levels are allowed to partially recover Groundwater samples(both <br /> purge and no-purge) are collected using a clean disposable Teflon@ bailer, placed into appropriate EPA-approved <br /> containers, labeled, logged onto chain-of-custody documents, and transported on ice to a California state-certified <br /> laboratory <br /> Decontamination Procedures <br /> Prior to sampling each well,reels and pumps will be decontaminated with a steam cleaner Sensitive equipment such <br /> as the water level sounder are sprayed with a non-phosphate soap and deiomzed water solution and rinsed with <br /> deionized water All water used for equipment decontamination is collected and contained in a truck-mounted water <br /> tank <br /> Laboratory Procedures <br /> The groundwater samples are analyzed for the presence of the following TPHg and BTEX using EPA Methods <br /> 8015 (modified) and 8021 Oxygenates are analyzed using EPA Method 8260B The methods of analysis for the <br /> groundwater samples are documented in the laboratory analytical report The laboratory analytical report,chain-of- <br /> custody documentation,and field data sheets are presented as Appendix B <br /> Purge and Rinsate Water Disposal <br /> Water generated during well sampling and equipment cleaning is pumped into a truck-mounted water tank The <br /> water is transported to the Blaine Tech Services holding facility in Roseville, California, or in the ARCO holding <br /> facility in West Sacramento, California, for temporary storage Dillard Environmental Services then transports the <br /> water to the Altamont Landfill and Resource Recovery Facility in Altamont,California,for disposal <br /> • <br /> K\f5 BP nRC010608MQuorcerW_QTR 0216080 GWMR3Q02 do Page A-1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.