Laserfiche WebLink
GEORGE SCHULER INC. <br /> 1705 N. Broadway, Stockton, California <br /> Remedial Excavation Report <br /> 1.0 PROJECT IDENTIFICATION <br /> This project involved the removal of oil contaminated soil caused by an underground <br /> storage tank release at the property at 1705 N. Broadway in Stockton, California (Figure <br /> 1). The remedial excavation work included confirmation sampling of the floor and <br /> sidewalls of the excavation. <br /> 1.1 Site Description and History <br /> On August 27, 1992 SEMCO, under permit, removed two (2) underground <br /> gasoline storage tanks along with the associated piping. Soil samples taken at 15 <br /> feet in depth disclosed high concentrations of gasoline, Benzene, Toluene, <br /> Xylenes, and Ethyl Benzene(BTX&E). <br />'. A Re-Excavation Work Plan, dated October 7, 1992, was submitted by SEMCO <br /> to the San Joaquin County Environmental Health Department. The work plan <br /> proposed an excavation 25 by 25 feet wide to a maximum depth of 30 feet and <br /> logged by WHF Environmental Consultants' registered geologist. <br /> 2.0 SCOPE OF WORK <br /> On October 27, 1992 SEMCO re-excavated the former underground tank faciliry at <br /> George Schuler's. WHF screened the soil with a portable PID and logged the excavaxion. l <br /> Highly contaminated soils were encountered during the excavation but appeared to beu� I <br /> intermittent and layered instead of decreasing in concentration consistently with depth. At <br /> a depth of 30 feet gasoline odor was still present in the soil from the floor and sidewalls of <br /> the excavation. The excavation was terminated at this depth and samples were taken, <br /> under the direction of the local regulatory agent. The final lateral dimensions of the <br /> excavation were 21 by 17.5 feet (Figure 2). <br /> 'Soil samples taken, for laboratory analysis, of the side walls at varying depths were non <br /> detect for gasoline and BTX&E. The floor sample taken at 30 feet in depth disclosed <br /> concentrations of gasoline along with BTX(Table 1 & Appendix A). <br /> I <br />