Laserfiche WebLink
South San Joaquin Irrigation District <br /> DRAFT Lead Assessment&Soil Relocation Work Plan <br /> For Discussion Purposes Only. Do Not Distribute July 5, 2017 <br /> Up to approximately 100 lead pellets/sq ft are present on the canal banks and road and <br /> approximately 10 lead pellets/sq ft are on the canal bottom. Shot sizes for trap shooting include 7 '/2, <br /> 8, and 8 '/2. These sizes translate to a diameter of 0.095", 0.090", and 0.085", respectively. <br /> 3.0 Soil Sampling and Testing <br /> Soil samples will be collected on SSJID's property using the grid shown on Figure 5. Depending on <br /> field conditions, samples will be collected by either shovel and hand trough or a driven brass sleeve <br /> sampler. <br /> The grid on Figure 5 consists of thirty three (33) 50' x 50' squares. Initially, two samples will be <br /> collected in the approximate center of each grid. <br /> The first sample will be collected from a depth of between 0-12 inches and analyzed to determine if <br /> soil with visible lead pellets in it meets the criteria for California Restricted hazardous waste and/or <br /> Resource Conservation and Recovery Act (RCRA) hazardous waste by exceeding the lead Total <br /> Threshold Limit Concentration (TTLC) of 50 mg/Kg. Depending on the laboratory results, additional <br /> testing to assess the Soluble Threshold Limit Concentration (STLC) may be done. Depending on <br /> both STLC and TTLC results, Toxicity Characteristic Leaching Procedure (TCLP) analysis may also <br /> be conducted. <br /> If the first sample meets or exceeds hazardous waste criteria, a second sample will be collected <br /> beneath the first sample and approximately 6" beneath the deepest location that lead pellets are <br /> observed and analyzed to confirm that soil in this horizon does not exceed hazardous waste criteria. <br /> If soil in this horizon exceeds hazardous waste criteria, additional deeper sample(s) will be collected <br /> at 6 inch intervals and analyzed until soil does not exceed hazardous waste criteria. <br /> All samples will be analyzed by EPA Method EPA 7420, EPA 6010 equivalent. Sampling <br /> equipment will be thoroughly cleaned be en sample locations to prevent cross-contamination. <br /> One (1) duplicate and one (1) equipment blank sample will be collected during collection of every 20 <br /> field samples for QA/QC purposes and in order to assess sampling accuracy and precision. <br /> Page 9 Blankinship & Associates , Inc . <br />