My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE HISTORY
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUSINESS LOOP 205
>
5157
>
3500 - Local Oversight Program
>
PR0544135
>
SITE HISTORY
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2019 10:21:39 AM
Creation date
2/12/2019 10:02:15 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
SITE HISTORY
RECORD_ID
PR0544135
PE
3528
FACILITY_ID
FA0005488
FACILITY_NAME
STRONG, RUTH
STREET_NUMBER
5157
Direction
W
STREET_NAME
BUSINESS LOOP 205
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
5157 W BUSINESS LOOP 205
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
100
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
29 April 2 005,., <br /> AGE-NC Project-No' 98-0440 ` <br /> Page 4 of 18 . <br /> . .. TAK ' <br /> ,.a h <br /> 3:0.: ASSESSMENT OF'HYDROCARBON-IWACTED SOEL AND GROUND WATER <br /> The.followingis a.brief summ <br /> ary.of site assessment activities:'�, r <br /> h.1998 Six soil borings (B1 through B6) and four ground water monitoring wells <br /> (MW-1.through MW-4) were installed at the site'to assess the4ateral and vertical extent of <br /> impacted soil and ground water.A totalof 23 soil sample's and four ground Water monitoring., ' <br /> . <br /> •well .samples were-collected during the inve'stigation•and. were submitted for laboratory' <br /> analysis,Total petroleum hydrocarbons quantified as gasoline and diesel(TPH-g and TPH-d, <br /> respectively) were• detected in analyzed -soil samples at '`concentrations as high as <br /> •: - ' 58Q•milligram's per kilogram (Mg/kg) ,dissolved TPH-g and'.'TPH-d were.detected from <br /> E . ' <br /> 'ground water monitoring'well samplcs'at concentrations ranging as high as 2,400µg11.BTEX.- <br /> compounds were detected in selected'soil samples and ground water monitoring well. <br /> samples'at concentrations as-high as 32 mg/kg and 36µg/l,respectively.Boring locations are <br /> depicted in Figure 2 and analytical results of soil and ground water samples are presented in ' <br /> Tables 3 and 4.A report of findings(Preliminary Investigation"&Eval uativn Report, dated <br /> 14 September 1998)was siibmitted by AGE to the'SJCEHD. <br /> May 2000- Three soil borings (B7, MW5 and MW6)were advanced at the site; two of the <br /> boring's were completed as monitoring wells MW-5 and MW-6. TPH- <br /> g was detected in the . <br /> i 15-foot soil sample'ana!yzed from boring MW6 at a concentration of 330-mg/kg._TPH-d was <br /> detected in MW5,MW6,and B7 at concentrations as high as 1.40 mg/kg(MW6-15). BTEX <br /> compounds were detected in the 15-foot soil sample from MW6 at concentrations of 0:094 <br /> E mg/kg,'16.mg/kg, 8.7 mg/kg and 2.8 mg/kg, respectively. Boring locations are depicted in <br /> Figure 2.and analytical results of soil.and ground water sa%nples-are presented in Tables 3 and <br /> 4. A'repart of findings (Quarterly Report Second Quarter 2000, dated 09•August 2000.) <br /> was submitted by AGE to the SJCEHD.. <br /> ,. t <br /> E <br /> -January,2002- Two soil.probe borings B8 and 139.were'advan8ed utilizing vain=mounted • " <br /> Geoprobe 5400 equipped with l.125-inch diameter probe rods with an•attaclied 2.15-inch <br /> diameter soil;sample`r,'yertically to depths'of 60 feet bsg':`Grafi:`ground water samples were <br /> collected from each probe boring using a Geoprobe hyd'ropurich sampling assembly: The ` <br /> probe rods were advanced.to'approximately.60 feet bsg.TPH,g was detected in the water <br /> samples collected from B$ and B9 at'concentrations of.71µg11 and 8.8 µg/1, respectively. <br /> TPH-d was detected.in the water sample collected from.B9 at a concentration of 140 µg/1. <br /> benzen' and total xylenes were detected in the sample from B8 at concentrations of 1.2- <br /> Ethyl.; 1 and 13 res ectivel Toluene eth lbenze' and total;x lenes were detected in.the <br /> n/ µms, P Y Y Y. <br /> water sample collected from b6ringB9 at concentrations of 0.6jµg11,0:72µg/1 and 43 µg/1; <br /> respectively.`No other analytes including benzene were detected at'-or above laboratory <br /> reporting limits in the grab ground water samples,analyzed.Boring locations are depicted in <br /> Figure 2'and analytical results of,grab ground.water samples are presented in.Table 4.'A <br /> Advanced GeoEnvironmenta4 Inc. <br />