Laserfiche WebLink
110 2nd Ave.South,#D7,Pacheco,CA 94553-5560 <br /> KMcCC <br /> AMPBELL ANALYTICAL INC. Telephone:925-798-1620 Fax: 925-798-1622 <br /> h ://www.mcc a .com E-mail:main@mccampbell.cow <br /> QC REPORT <br /> Date: 09101100-09/02/00 Matrix: Water <br /> Extraction: NIA <br />' Concentration: ug/L %Recovery <br /> Compound Amount RPD <br /> Sample ; MS MSD Spiked MS MSD <br /> ISamplelD: 9100 Instrument: GC-3 <br />' Surrogatel 0.000 99,0 99.0 100.00 99 99 0.0 <br /> Xylenes 0.000 296.0 293.0 300.00 99 98 1.0 <br /> ! Ethyl Benzene 0.000 98.0 97.0 100.00 98 97 1.0 <br />' Toluene 0.000 101.0 101.0 100.00 101 101 0.0 <br /> Benzene 0.000 103.0 ; 103.0 100.00 103 103 0-0 <br />' MTBE 0.000 106.0 108.0 100.00 106 108 1.9 <br /> GAS 0.000 871.9 894.3 1000.00 87 89 2.5 <br />' SampleID: 9300 Instrument GC-118 <br /> ! Surrogatel 0.000 112.0 111.0 100.00 112 111 0.9 <br />' TPH (diesel) 0.000 317.0 294.0 300.00 106 98 7.5 ! <br /> I <br /> I <br /> 1 <br /> MS--Sample) <br />' M Re covery a AmoundpiW '100 <br /> MS-MSD <br /> RFD= -2-100 <br />' (MS+MSD) <br /> RPD means Relative Percent Deviation <br />