My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000992
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUSINESS LOOP 205
>
5157
>
3500 - Local Oversight Program
>
PR0544135
>
ARCHIVED REPORTS XR0000992
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2019 10:44:46 AM
Creation date
2/12/2019 10:14:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000992
RECORD_ID
PR0544135
PE
3528
FACILITY_ID
FA0005488
FACILITY_NAME
STRONG, RUTH
STREET_NUMBER
5157
Direction
W
STREET_NAME
BUSINESS LOOP 205
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
5157 W BUSINESS LOOP 205
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
c - <br /> C. . _ '.Quarterly Report -.First Quarter 2005 <br /> STRONG PROPERTY _ <br /> 5157-W6t Business Loop.Z05,Tracy,-California Y _ <br /> '1.0..- INTRODUCTION. <br /> . , .fir ~ 9 <br /> At the request-of Messrs. Robert and Mike Strong,Advanced GeoEnvironmental, Inc. (AGE) has _ <br /> prepared this-quarterly report for.the property located,at-5157 West Business Loop:2059 Tracy, <br /> I p of work included-the performance of a quarterly ground water monitoring <br /> Callfartna..The scope p <br /> event and preparation of this report.-The site.and the surrounding area are illustrated on:Figure 1. <br /> Structures and monitoring well locations are illustrated-,on Figure 2.Quarterly monitoring data from .. . <br /> July.1998 to the present is summarized in the tables.-of this report. Historical site investigation <br /> - information is summarized.in Appendix A. GeoTracker confirmation.pages of the submitted depth <br /> to water and.laboratory electronic deliverable fonnat (EDF) files are.included.in Appendix B. . <br /> 2.0. . PROCEDURES y <br /> On26 March 2005,twelve rrionitoring wells(MW-1 through MW-12)arid two domestic water wells <br /> (DW5157 and DW5055) were purged and sampled. All field work.procedures and reporting . <br /> requirements are in accordance with guidelines issued by the Central Valley Regional Water_Quality <br /> #~ Control Board(CVRWQCB)for subsurface°investigations.of underground storage tank(UST)sites <br /> r' and uidelines-issued b San Toa uin Couri •Environmental Health Department(EHD}far sampling =• " <br /> g Y q - tY _ - <br /> of ground water monitoring wells. <br /> 2'.1. WELL MONITORING AND PURGING <br /> On-26 March 2005;monitoring wells MW-1 through MW42 and domestic water wells DW5157 ; <br /> - -and DW5055 were purged and sampled A Solinst-water level meter was used to measure the depth <br /> to groundwater to the nearest 0.01=foot in the twelve monitoring well relative to the tops of the well <br /> casings. The ground water elevations and gradient were determined from these.data{TableWSW <br /> After recording water level,measurements, new disposable_plastic bailers were:used to purge each.' <br /> monitoring well of standing water.Between 4 and 7.5,gallons ofwater(a mitumum of 3 casing-water <br /> volumes per well)were removed from each well.-Ground water temperature,pH and conductivity <br /> r}' were measured,at'regular intervals during purging using an Oakion water analyzer.. To purge <br /> DW5157 and DW5055, a hose:bib was opened on the water storage tank. The pump-was allowed... <br /> to cycle on and off for approximately 15 minutes,--,Field'sheets and data are included in Appendix C. <br /> Purged water was stored on-site in labeled,55-gallon'Department of Transportation-(DOT)-approved " <br /> drums. " <br /> - _. Advanced GeoEnviroumental,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.