My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012814
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BUSINESS LOOP 205
>
5157
>
3500 - Local Oversight Program
>
PR0544135
>
ARCHIVED REPORTS XR0012814
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/12/2019 10:40:31 AM
Creation date
2/12/2019 10:14:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012814
RECORD_ID
PR0544135
PE
3528
FACILITY_ID
FA0005488
FACILITY_NAME
STRONG, RUTH
STREET_NUMBER
5157
Direction
W
STREET_NAME
BUSINESS LOOP 205
City
TRACY
Zip
95376
CURRENT_STATUS
02
SITE_LOCATION
5157 W BUSINESS LOOP 205
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
52
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Quarterly Reports First.Quarter 2001 <br /> STRONG PROPERTY <br />' <br /> 5,157 West Business Loop 2.05, Tracy,;California. <br /> 1.4.. INTRODUCTION ± <br /> At the request.of Ms. Ruth Strong,Advanced'GeoEnvironmental,-Inc. (AGE) has prepaired'this <br />' quarterlyreport for the properi ,located "at 5157 West Business Loo 205, Tracy, California. The <br /> P p p . y p Y r <br /> scope of work completed during the quarter included ground water sampling of monitoring wells ; <br /> MWI through MW6, the,domestic Well-located at 5157 West Business Loop 205 (DW5157) and <br />'1 preparation of this report. Also included is a site conceptual,model as required by"the,San Joagiuiri <br /> County Public Health Services - Environmental Health Division (PHS-EHD) by letter dated 16 <br /> Janilary.2001. The site and,the surrounding area are illustrated in Figure 1. Structures and monitoring,. <br /> well locations are illustrated on Figure 2. <br /> IBackground -in.formation is summarized in the AGE-prepared document .titled Additio'nal.'Site <br /> Assessment Work Plan,Addendum, dated 01 July 2000. Quarterly monitoring'data from July 19.98 <br /> to the present is.summarized in Tables 1 and 2 of this report: ' <br /> 2.0. PROCEDURES <br /> Field work,was performed in accordance with guidelines developed by the San'Joaquin County ; <br /> PHS-,EHD and the Central Valley Regional Water Quality Control Board(CVRWQCB)for sampling <br /> ground water monitoring wells and for investigating underground storage tank (UST) sites. <br /> 2.1 -MONITORING WELL PURGE PROCEDURES ; <br /> Sampling of ground water monitoringwells MWI .through MW6 and,domestic well DW5157 <br /> I'. occurred on 15 March 2001.For the g sam lin event•aSolinst.water level meter was used to measure <br /> p � ' y .. . <br /> the depth to groundwater in the six monitoring wells relative to.the tops of the well casings..The <br /> ground water elevations and gradient were determined from these data(Table 1). <br /> After recording water level measurements, a submersible pump was used to purge each monitoring. <br /> Iwell of standing water. Approximately 5 'to 8.'gallons of water (a minimum of 3 casing-water <br /> ,volumes) were removed from"each well. Ground water temperature, pH and conductivity were <br /> measured at-regular intervals during purging,using an Oakton water analyzer. Field sheets and data ,- <br />' are included�in Appendix A. Purged water`was stored on-site in labeled, 55=gallon"DOT-approved` <br /> drums. <br /> Advanced GenEnvironmental,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.