My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2003 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:40:16 PM
Creation date
2/13/2019 2:56:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2009
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONI )RING SYSTEM CERTIFY -'ATIOR E I <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.• Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code ofR� 18 <br /> u t <br /> A 2008 <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tanl�, tW�6ff" <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. ENVIRONMENTAL <br /> A. General Information HEALTH DEPARTMENT <br /> Facility Name: ARP MINI MART Bldg.No.: <br /> Site Address: 25775 S. Patterson Road City: Tracy Zip: 95376 <br /> Facility Contact Person: Neilsh Patel Contact Phone No.: (209) 835-7777 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 4/4/2008 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a !! ment inspected/serviced: <br /> Tank tD: T2: 87 Blue Master Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑FRI Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ®Electronic Line Leak Detector. Model: 8484 S#HX030 ❑Electronic Line Leak Detector. Model: <br /> []'Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank 1D: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> 'If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ❑ System set-up ®Alarm history report 00,1 Cup' Q1 A Uke- to <br /> � Ce.a� G�rn2n�, <br /> Technician Name(print): Guadalupe Sanchez Signature <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: RELIABLE PETROLEUM SERVICES INC. Phone No.: (209) 845-8586 <br /> Testing Company Address: 521 Branding Iron St. Oakdale Ca. 95361 Date of Testing/Servicing: 4/04/2008 <br /> Page 1 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.