My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2003 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
COMPLIANCE INFO 2003 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/14/2019 1:40:16 PM
Creation date
2/13/2019 2:56:17 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003 - 2009
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITOJNG SYSTEM CERTIFIC,. TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of thi Epe tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST s ti ate. <br /> A. General Information <br /> Facility Name: ARP MINI MART APR 2 12009 <br /> Bldg.No.: <br /> Site Address: 25775 S. Patterson Pass Road city: UNMENT HEALTH Zip: 95376 <br /> Facility Contact Person: Nailsh Patel Co 835-7777 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 3/27/2009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the approuriate boxes to indicate s cific equipment inspected/serviced: <br /> FTank 1D: T1: 87 Blue Slave Tank 1D: T2: 87 Blue Master <br /> n-Tank Gauging Probe. Model: 847390-107 ®In-Tank Gauging Probe. Model: 847390-107 <br /> nnular Space or Vault Sensor. Model: 794390-407 Z Annular Space or Vault Sensor. Model: 794390-407 <br /> iping Sump/Trench Sensor(s). Model: 794380-208 Z Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ®Fill Sump Sensor(s). Model: 794380-208 ®Fill Sump Sensor(s). Model: 794380-208 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: Z Electronic Line Leak Detector. Model: 8484 <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: 87 Blue Syphon Tank ID: T4: 91 Gold <br /> Z In-Tank Gauging Probe. Model: 847390-107 Z In-Tank Gauging Probe. Model: 847390-107 <br /> Z Annular Space or Vault Sensor. Model: 794390-407 Z Annular Space or Vault Sensor. Model: 794390-407 <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-208 Z Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> Z Fill Sump Sensor(s). Model: 794380-208 Z Fill Sump Sensor(s). Model: 794380-208 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: Z Electronic Line Leak Detector. Model: 8484 <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1 &2 Dispenser ID: 3&4 <br /> ®Dispenser Containment Sensor(s). Model: 794380.208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5&6 Dispenser ID: 7&8 <br /> Z Dispenser Containment Sensor(s). Model: 794380-208 Z Dispenser Containment Sensor(s). Model: 794380-208 <br /> Z Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 1D: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,l have also <br /> attached a copy of the report;(check all that apply): Z System set-up Z Alarm history report <br /> Technician Name(print): Guadalupe Sanchez Signature: ems <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 521 Branding Iron St. Oakdale Ca.95361 Date of Testing/Servicing: 2/27/2009 <br /> Page 1 of 4 <br /> Rev(2/08) <br />