My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
BILLING 2003 - 2009
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
P
>
PATTERSON PASS
>
25775
>
2300 - Underground Storage Tank Program
>
PR0231708
>
BILLING 2003 - 2009
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/4/2023 1:10:44 PM
Creation date
2/13/2019 4:09:23 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
BILLING
FileName_PostFix
2003 - 2009
RECORD_ID
PR0231708
PE
2361
FACILITY_ID
FA0003619
FACILITY_NAME
ARP MINI MART CORP
STREET_NUMBER
25775
Direction
S
STREET_NAME
PATTERSON PASS
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
20910004
CURRENT_STATUS
01
SITE_LOCATION
25775 S PATTERSON PASS RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
60
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
`.FLED PROGRAM CONSOLIDATED FORMTANK: T:AL0I70807 <br /> ' PR#: PRO231708 <br /> UNDERGROUND STORAGE TANKS - TANK PAGE 1 V/�,�9� FAC#: FA0003619 <br /> 5 (two pages per tank) <br /> TYPE OF ACTION Page 2 of 9 <br /> (Check only item only) ❑ 1 NEW SITE PERMIT ❑ 4 AMENDED PERMIT ❑ 5 CHANGE OF INFORMATION E] 6 TEMPORARY SITE CLOSURE <br /> ❑ 7 PERMANENTLY CLOSED ON SITE <br /> ❑ 3 RENEWAL PERMIT (Specify reason-for local use only) (Spee y reason•for local use only) ❑8 TANK REMOVED <br /> 430 <br /> BUSINESS NAME(Same as FACILITY NAME or DBA-Doing Business As) 11 FACILITY ID: PR#: <br /> ARP MINI MART CORP 3 FA0003619 PR0231708 <br /> LOCATION WITHIN SITE(Optional) 25775 S PATTERSON PASS RD,TRACY 43 <br /> PHONE <br /> I.TANK DESCRIPTION(A scaled plot plan with the location of the UST system including buildings and landmarks shall be submitted to the local agency.) <br /> TANK ID# Tank#: 7 432 TANK MANUFACTURER 433 COMPARTMENTALIZED TANK ❑Yes ❑No 434 <br /> TA0170807 If"Yes",complete one page for each compartment. <br /> DATE INSTALLED(YEAR/MO) 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS 437 <br /> 10,000 <br /> ADDITIONAL DESCRIPTION(For local use only) 438 <br /> II.TANK CONTENTS <br /> TANK USE 439 PETROLEUM TYPE 440 <br /> ® 1.MOTOR VEHICLE FUEL ® 1 a.REGULAR UNLEADED ❑2.LEADED ❑ 5.JET FUEL <br /> (Ifmarked wmplete Petroleum Type) ❑ lb.PREMIUM UNLEADED ❑3.DIESEL ❑6.AVIATION FUEL <br /> ❑2.NON-FUEL PETROLEUM ❑ 1 c.MIDGRADE UNLEADED ❑4.GASOHOL ❑ 99.OTHER <br /> ❑3.CHEMICAL PRODUCT <br /> COMMON NAME(fmm Hazardous Materials Inventory page) 441 CAS#(from Hazardous Materials Inventory page) 442 <br /> ❑4.HAZARDOUS WASTE <br /> Qncludes Used Oil) <br /> ❑95.UNKNOWN <br /> III.TANK CONSTRUCTION <br /> TYPE OF TANK ❑ I.SINGLE WALL ❑ 3.SINGLE WALL WITH ❑ 5.SINGLE WALL WITH INTERNAL BLADDER SYSTEM 443 <br /> (Check one item only) EXTERIOR MEMBRANE LINER ❑ 95.UNKNOWN <br /> ® 2.DOUBLE WALL ❑4.SINGLE WALL IN VAULT ❑ 99.OTHER <br /> TANK MATERIAL-primary tank ❑ 1.BARE STEEL ❑ FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑ 95.UNKNOWN 444 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑ STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/100%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 99.OTHER <br /> TANK MATERIAL-secondary tank ❑ 1.BARE STEEL ❑ 3.FIBERGLASS/PLASTIC ❑ 5.CONCRETE ❑95.UNKNOWN 445 <br /> (Check one item only) ❑ 2.STAINLESS STEEL ❑4.STEEL CLAD W/FIBERGLASS ❑ 8.FRP COMPTIBLE W/!00%METHANOL <br /> REINFORCED PLASTIC(FRP) ❑ 10.COATED STEEL ❑99.OTHER <br /> ❑ 5.CONCRETE <br /> TANK INTERIOR LINING ❑ 1.RUBBER LINED ❑3.EPDXY LINING ❑ 5.GLASS LINING ❑95.UNKNOWN 446 DATE INSTALLED 447 <br /> OR COATING <br /> (Check one item only ❑ 2 ALKYD LINING ❑4 PHENOLIC LINING ❑ 6 UNLINED ❑ 99 OTHER <br /> (For local use only) <br /> OTHER CORROSION ❑ I MANUFACTURING CATHODIC ❑ 3 FIBERGLASS REINFORCED PLASTIC ❑ 95 UNKNOWN 448 DATE INSTALLED 449 <br /> PROTECTION IF APPLICABLE PROTECTION <br /> (Check one item only) ❑4 IMPRESSED CURRENT E] 99 OTHER <br /> ❑ 2 SACRIFICIAL ANODE (For local use only) <br /> SPILL AND OVERFILL YEAR INSTALLE45e TYPE yowl use only 451 OVERFILL PROTECTION EQUIPMENT:YEAR INSTALLED 452 <br /> (Check all that apply) ❑ I SPILL CONTAINMENT <br /> ❑ 1 ALARM ❑3 FILL TUBE SHUT OFF VAL` <br /> ❑ 2 DROP TUBE ❑ 2 BALL ❑ 4 EXEMPT <br /> ❑ 3 STRIKER PLATE FLOAT <br /> IV.TANK LEAK DETECTION(A description of the monitoring program shall be submitted to the local agency.) <br /> IF SINGLE WALL TANK(Check all that apply) 453 IF DOUBLE WALL TANK OR TANK WITH BLADDER 454 <br /> ❑ I VISUAL(EXPOSED PORTION ONLY) ❑ 5 MANUAL TANK GAUGING(MTG) (Check one item only) <br /> ❑ 2 AUTOMATIC TANK GAUGING(ATG) ❑ 6 VADOSE ZONE <br /> ❑ I VISUAL(SINGLE WALL IN VAULT ONLY) <br /> ❑ 3 CONTINUOUS ATG ❑ 7 GROUNDWATER ®2 CONTINUOUS INTERSTITIAL MONITORING <br /> ❑4 STATISTICAL INVENTORY RECONCILIATION ❑ 8 TANK TESTING ❑3 MANUAL MONITORING <br /> (SIR)BIENNIAL TANK TESTING ❑ 99 OTHER <br /> V.TANK CLOSURE INFORMATION/PERMANENT CLOSURE IN PLACE <br /> ESTIMATED DATE LAST USED(YR/MO/DAY) 455 1 ESTIMATED QUANTITY OF SUBSTANCE REMAINING 456 TANK FILLED WITH INERT MATERIAL? 457 <br /> ❑Yes ❑ No <br /> UPCF(12/99 revised) <br />
The URL can be used to link to this page
Your browser does not support the video tag.