Laserfiche WebLink
" A <br /> UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> OPERATING PERMIT APPLICATION-TANK INFORMATION (One form per UST) <br /> TYPE OF ACTION (Check one item only. For a UST closure or removal,complete only this section and Sections I,II.III,IV,and IX below) OU <br /> ❑ L NEW PERMIT ❑ 3.RENEWAL PERMIT S.CHANGE OF INFORMATION <br /> 6.TEMPORARY UST CLOSURE 7.UST PERMANENT CLOSURE ON SITE 8.UST REMOVAL <br /> DATE UST PERMANENTLY CLOSED: 4301 DATE EXISTING UST DISCOVERED: 4306 <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) D - 1 <br /> BUSINESS NAME(Same as Facility Name or DBA-Doing Business As) 3. <br /> ARP mwimPOLT ( UNION 76) <br /> BUSINESS SITE ADDRESS 163. CITY 1o4 <br /> 2 5 5 S . P�r� l" as o r� F�Flss TR R G <br /> II. TANK DESCRIPTION <br /> TANK ID# q 432 TANK MANUFACTURER 433. TANK CONFIGURATION:THIS TANK IS 434. <br /> x e S ❑❑ 2.AOI E IN STAND-ALONE <br /> RTMTMENTED UNIT COMPLas °�`��, <br /> mens in the wh. <br /> DATE UST SYSTEM INSTALLED 435 TANK CAPACITY IN GALLONS 436 NUMBER OF COMPARTMENTS IN THE UNIT 437. <br /> Iq 3 0 000 1ONE <br /> III. TANK USE AND CONTENTS <br /> TANK USE ® Is.MOTOR VEHICLE FUELING ❑ 1b.MARINA FUELING ❑ 1c.AVIATION FUELING 439. <br /> ❑ 3.CHEMICAL PRODUCT STORAGE ❑ 4.HAZARDOUS WASTE(Inch da Used Oiq ❑ 5.EMERGENCY GENERATOR FUEL[HSC f25231.5(c)] <br /> ❑ 6.OTHER GENERATOR FUEL_ ❑ 95.UNKNOWN _ ❑ 99.OTHER(Specify): 439a <br /> CONTENTS PETROLEUM: ® Ia.REGULAR UNLEADED ❑ Ic.MIDGRADE UNLEADED ❑ 1b.PREMIUM UNLEADED iuo <br /> ❑ 3.DIESEL ❑ 5.JET FUEL ❑ 6.AVIATION GAS <br /> _ [19.PETROLEUM BLEND FUEL _❑ 9.OTHER PETROLEUM(Specify): 440a. <br /> NON-PETROLEUM:❑ 7.USED 011. ❑ 10.ETHANOL <br /> ❑ I I.OTHER NON PETROLFUM 440e. <br /> IV. TANK CONSTRUCTION <br /> TYPE OF TANK ❑ 1.SINGLE WALL t5 2.DOUBLE WALL ❑ 95.UNKNOWN 441 <br /> PRIMARY CONTAINMENT ❑ 1.STEEL 01 3.FIBERGLASS ❑ 6.INTERNAL BLADDER 444. <br /> ❑ 7.STEEL+INTERNAL LINING ❑ 95.UNKNOWN ❑ 99.OTHER ify): 444a. <br /> SECONDARY CONTAINMENT ❑ I.STEEL ®3.FIBERGLASS ❑ 6.EXTERIOR MEMBRANE LINER ❑ 7.JACKETED 445. <br /> ❑ 90.NONE ❑ 95.UNKNOWN (]99.OTHER(Specify): 4454L <br /> OVERFILL PREVENTION ($ L AUDIBLE do VISUAL ALARMS ® 2.BALL FLOAT ❑ 3.FILL TUBE SHUT-OFF VALVE 452. <br /> 4.TANK MEETS REQUIREMENTS FOR EXEMPTION FROM OVERFILL PREVENTION E MM04T <br /> V. PRODUCT/WASTE PIPING CONSTRUCTION <br /> PIPING CONSTRUCTION _-Q 1.SINGLE WALL C1 2-DOUBLE WALL_ 0 99 OTHER _ ____�_ 460 <br /> SYSTEM TYPE �® 1_PRESSURE ❑ 2.GRAVITY (] 3.CONVENTIONAL SUCTION 0-4.SAFE SUCTION[23 CCR¢x63e,X3fl 439 <br /> PRIMARY CONTAINMENT 0 I.STEEL ❑ a.FLEXIBLE ❑ 10.RIGID PLASTIC 4� <br /> ❑ 90.NONE ❑ 95.UNKNOWN ❑ 99.OTHER(Specify): 464` _ <br /> SECONDARY CONTAINMENT ❑ 1.STEEL 0 a.FQiE RGLASS ❑ S.FLEXIBLE ❑ 10.RIGID PLASTIC 464b, <br /> ❑ 90.NONE ❑ 95.UNKNOWN 0 99.OTHER(Specify): 464c. <br /> P�]NC,/TURBINFi CONTAINMENT SUMP TYPE ej 1.SINGLE WALL ❑ 2.DOUBLE WALL ❑ 90.NONE 464d <br /> VI. VENT,VAPOR RECOVERY(VR)AND RISER/FILL PIPE PIPING CONSTRUCTION <br /> VENT PRIMARY CONTAINMENT ❑ 1.STEEL ®4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE ❑ 99.OTHER(Specify): 464e1. <br /> VENT SECONDARY CONTAINMENT ❑ 1.STEEL [34.FIBERGLASS ❑ 10.RIGID PLASTIC �90.NONE ❑ 99.OTHER(Specify): 40'/' <br /> _ _ ,ban. <br /> VR PRIMARY CONTAINMENT ❑ 1.STEEL ® 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 90.NONE E399.OTHER(Specify): 4"9.VR SECONDARY CONTAINMENT [31.STEEL ❑ 4.FIBERGLASS [310.RIGID PLASTIC C9 90.NONE ❑ 99.OTHER(SpecifY)- bj <br /> VENT PIPING TRANSITION SUMP TYPE [31.SINGLE WALL E32.DOUBLE WALL CW 90.NONE - 464i. <br /> RISER PRIMARY CONTAINMENT IN I.STEEL ❑ 4.FIBERGLASS ❑ 10.RIGID PLASTIC ❑ 9o.NONE ❑ 99.OTHER(specify): <br /> RISER SECONDARY CONTAINMENT ❑ I.STEEL Ja 4.FIBERGLASS ❑ 10.RIGID PLASTIC [3 90.NON: ❑ 99.OTHER(SpecifY): 4664k1. <br /> FILL COMPONENTS INSTALLED W 1$( I.SPILL BUCKET ® 3.STRIKER PLATFJBOTTOM PROTECTOR 9 4.CONTAINMENT SUMP 431 a-c. <br /> VII. UNDER DISPENSER CONTAINMENT(UDC) <br /> CONSTRUCTION TYPE! _ ® 1.SINGLE WALL _ ❑ 2.DOUBLE WALL C1 3.NO DISPENSERS ❑ 90.NONE _ 469a <br /> CONSTRUCTION MATERIAL [31.STEEL ® 4.FIBERGLASS [310.RIGIDPLASTIC 1399.OTHER(Specify) 446ya <br /> VIII. CORROSION PROTECTION <br /> STEEL COMPONENT PROTECTION ❑ 2.SACRIFICIAL ANODE(S) ❑ 4.IMPRESSED CURRENT 6.ISOLATION at• 448. <br /> IX. APPLICANT SIGNATURE <br /> CERTIFICATION: I certify that this UST system Is compatible with the hazardous substance stored and that the Information provided bejdn is true, <br /> accurate,and In full com Liance with legal requirements. <br /> APPLICANT SIGNATURE DATE 1 L2002azo. <br /> APPLICANT NAME(print) 471 APPLICANT TITLE 4n <br /> GiRATEL TRGASURE <br /> UPCF IJST-B Rev.(12/2007)-112 www.unidocs.org <br />