Laserfiche WebLink
A.r.�r ::A 5 5':U:: R A N <br /> kE::::F E R .FI:,N C E ':fi': A <br /> ., <br /> P The lower of the two values is reported when the % difference between the results of two GC columns is <br /> greater than 25%. <br /> Abbreviations <br /> A5 Post Digestion Spike (GFAA Samples - See Note 1 below) <br /> Batch designation given to identify a specific extraction, digestion, preparation set, or analysis set <br /> CAP Capillary Column CCB Continuing Calibration Blank <br /> CCV Continuing Calibration Verification <br /> CF Confirmation analysis of original <br /> 0 Confirmation analysis of Al or D1 <br /> C2 Confirmation analysis of A2 or D2 <br /> C3 Confirmation analysis of A3 or D3 <br /> CRA Low Level standard Check - GFAA; Mercury <br /> CRI Low Level Standard Check - ICP <br /> CV Calilbration Verification Standard <br /> Dil Fac Dilution Factor - Secondary dilution analysis <br /> D1 Dilution 1 <br /> D2 Dilution 2 <br /> 03 Dilution 3 <br /> DLFac Detection Limit Factor <br /> DSH Distilled Standard - High Level <br /> DSL Distilled Standard - Low Level <br /> DSM Distilled Standard - Medium Level <br /> EB1 Extraction Blank 1 <br /> E82 Extraction Blank 2 <br /> E83 DI Blank <br /> ELC Method Extracted LCS <br /> ELD Method Extracted LCD <br /> ]CAL Initial calibration <br /> ICB Initial Calibration Blank <br /> ICV initial Calibration Verification <br /> IDL Instrument Detection Limit <br /> ISA Interference Check Sample A ICAP <br /> ISB Interference Check sample 8 ICAP <br /> Job No. The first six digits of the sample ID which refers to a specific client, project and sample group <br /> Lab ID An 8 number unique laboratory identification <br /> LCD Laboratory Control Standard Duplicate <br /> LCs Laboratory Control Standard with reagent grade water or a matrix free from the anaLyte of interest <br /> MB Method Blank or (PS) Preparation Blank <br /> MD Method Duplicate <br /> MDL Method Detection Limit <br /> MLE Medium Level Extraction Blank <br /> MRL Method Reporting Limit Standard <br /> MSA Method of standard Additions <br /> MS Matrix Spike <br /> MSD Matrix spike Duplicate <br /> ND Not Detected <br /> PREPF Preparation factor used by the Laboratory's Information Management System (LIMB) <br /> PDS Post Digestion Spike (ICAP) <br /> RA Re-nnaLysis of original <br /> Al Re-analysis of D1 <br /> A2 Re-anBLyeis of D2 <br /> A3 Re-analysis of D3 <br /> RD Re-extraction of dilution <br /> RE Re-extraction, of original <br /> RC Re-extraction Confirmation <br /> RL Reporting Limit <br /> RPD Relative Percent Difference of duplicate (unrounded) analyses <br /> RRF Relative Response Factor <br /> Page 9 <br />