SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BYRON
>
0
>
2900 - Site Mitigation Program
>
PR0517323
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2019 3:46:08 PM
Creation date
2/14/2019 9:40:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0517323
PE
2960
FACILITY_ID
FA0013339
FACILITY_NAME
MT HOUSE SITES 1-6
STREET_NUMBER
0
STREET_NAME
BYRON
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
BYRON RD
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2890
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr. Robert Mihalovich <br /> Chevron Environmental Management Company <br /> April 4, 2002 <br /> Page 3 <br /> • A final report presenting a description of all field efforts; a discussion of results; <br /> characterization of site conditions (vertical and lateral extent of affected soil and <br /> groundwater); health risk assessment results; and appropriate recommendations will be <br /> submitted to the RWQCB for their approval. The report will also be submitted to the <br /> Department of Toxic Substances Control (DTSC) under the Voluntary Cleanup <br /> Program for DTSC approval of the health risk assessment. <br /> PROPOSED SCHEDULE <br /> In a memo dated October 19, 2001, Trimark presented their priority for addressing affected <br /> soil and groundwater. They divided the site into four segments and prioritized them based on <br /> their construction schedule (Figure 2). Geomatrix has developed a proposed investigation <br /> schedule that considers this prioritization (Figure 3). <br /> For purposes of developing this schedule, we have assumed that RWQCB will concur with <br /> using a self-directed approach and that two field investigation efforts will be necessary to <br /> collect sufficient data to fulfill the requirements of the CTA. We also have assumed that each <br /> field investigation will take approximately two months to complete. Each two-month period <br /> includes preparation of the work plan,permitting, coordination with subcontractors, conduct- <br /> ing field activities, and submittal of data in a brief report following receipt of analytical re- <br /> sults. The screening-level health risk assessment and final report will be completed within <br /> two months of completion of all investigation activities. <br /> Investigations at Sites 1 and 2 and at Sites 4 and 5 will be conducted concurrently due to their <br /> proximity to each other. Based on results of the investigations, additional work, such as <br /> groundwater monitoring, may be necessary at some sites. These potential additional activities <br /> have not been included in the schedule but will be performed in accordance with the CTA as <br /> necessary. <br /> We appreciate the opportunity to provide our consulting services to ChevronTexaco. Please <br /> call either of the undersigned if you have any questions. <br /> Sincerely yours, <br /> GEOMATRIX CONSULTANTS, INC. <br /> Jennifer L. Patterson, P.E. Gary R. Foote, R.G. <br /> Senior Engineer Principal Geologist <br /> ILP/GRF/pp <br /> I:1Doc Safe17000s%7243.0081Mtn House Undoc <br /> Attachments: Figures 1, 2, and 3 <br /> 2001 CTA <br />