My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SITE INFORMATION AND CORRESPONDENCE
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
B
>
BYRON
>
0
>
2900 - Site Mitigation Program
>
PR0517323
>
SITE INFORMATION AND CORRESPONDENCE
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2019 3:46:08 PM
Creation date
2/14/2019 9:40:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
SITE INFORMATION AND CORRESPONDENCE
RECORD_ID
PR0517323
PE
2960
FACILITY_ID
FA0013339
FACILITY_NAME
MT HOUSE SITES 1-6
STREET_NUMBER
0
STREET_NAME
BYRON
STREET_TYPE
RD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
BYRON RD
P_DISTRICT
005
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
2890
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TABLE 4 <br /> SUMMARY OF GROUNDWATER ANALYTICAL RESULTS (TPHd and BTEX) 1,2,3 <br /> MOUNTAIN HOUSE DEVELOPMENT SITE#6 <br /> Mountain House, San Joaquin County, California <br /> Concentrations in Itg/L unless noted <br /> Abbreviations: <br /> <=Denotes analyte not detected at or above the laboratory reporting limit <br /> BTEX=Benzene,toluene,ethylbenzene,and total xylenes <br /> D=Duplicate sample <br /> E=Estimated value based on surrogate recovery levels <br /> EPA=U.S.Environmental Protection Agency <br /> ESL=Environmental Screening Level <br /> G =Grab groundwater sample collected using peristaltic pump and prepacked well screen. <br /> HP=Depth-discrete sample collected using Hydropunch equipment,peristaltic pump,and pre-packed well screen <br /> ID=Identification <br /> NA=Not analyzed <br /> RWQCB=Regional Water Quality Control Board <br /> SAIC=Science Application International Corporation <br /> TPHd=Total petroleum hydrocarbons quantified as diesel,C10-C25 <br /> TPHdsg=Total petroleum hydrocarbons quantified as diesel with silica-gel cleanup <br /> WQO=Water Quality Objective <br /> µg/L=Micrograms per liter <br /> Notes: <br /> 1. Samples were collected by SAIC and analyzed by Lancaster Laboratories,Inc. TPHd were analyzed using EPA <br /> Method 8015 Modified performed both with and without a silica gel-preparation procedure. BTEX were analyzed <br /> using EPA Method 8260B. <br /> 2. Results in bold exceed WQOs and/or ESLs. <br /> 3. See Appendix E.1 for data usability summary. <br /> 4. WQO(Tastes and Odors)that prohibits adverse tastes and odors or nuisance conditions. <br /> 5. WQO(Toxicity)that prohibits toxic chemicals in toxic amounts. <br /> 6. ESL(for protection or current or potential drinking water resource)based on Ceiling Value. <br /> 7. ESL(for protection or current or potential drinking water resource)based on Drinking Water Toxicity. <br /> Sources: <br /> WQOs from the Central Valley Region RWQCB Water Quality Control Plan(Basin Plan)for the Sacramento <br /> River Basin and the San Joaquin River Basin,4th ed.(Revised August 2006). <br /> ESLs from the San Francisco Bay RWQCB Screening for Environmental Concerns at Sites with Contaminated <br /> Soil and Groundwater(Interim Final November 2007[Revised May 2008]). <br /> ---sG:,iii <br /> Page 2 of 2 From Science to sululivns <br />
The URL can be used to link to this page
Your browser does not support the video tag.