kn KLEINFELDER <br /> 5. Physical parameters (pH, electrical conductivity, and temperature) are monitored for <br /> stability while purging. The physical parameter measurements are recorded on purge- <br /> and-sample logs, along with the time and volume of water purged at each measurement. <br /> 6. Samples are collected with a disposable bailer or bladder pump into appropriately <br /> prepared bottles provided by the analytical laboratory. <br /> 7. Samples for metals analysis are usually filtered in the field at the time of collection. <br /> 8. Samples are immediately labeled and placed in an iced sample container. At the end of <br /> the day, the samples are delivered to the analytical laboratory under chain-of-custody <br /> control. <br /> B-5 Vadose Zone Monitoring <br /> 1. Prior to conducting lysimeter sampling, the pressure-vacuum equipment is checked and <br /> cleaned. A Soil-Moisture hand pump with a pressure-vacuum gage is used to measure <br /> residual and implied pressure-vacuum. Nitrogen gas is used to purge the lysimeter <br /> system for sampling. An air pump is available as a back up. <br /> 2. Approximately one week to one month prior to conducting the sampling, the residual <br /> pressures at the air-line of each lysimeter are measured ad the vacuums reset to <br /> manufactured recommended value (usually 50 centibars). The measurements and applied <br /> vacuums are noted on a sampling log form. Kleinfelder has found that resetting the <br /> lysimeters vacuums before the sampling yields good sample recovery. <br /> 3. The residual pressures are measured just prior to collecting the sample. The water line is <br /> then opened and nitrogen gas applied to the air line until either fluid or air is discharged <br /> (for dry lysimeters). The sample is contained in a 1 liter unpreserved bottle and the <br /> volume recovered is estimated. The fluid is then poured into appropriate preserved or <br /> unpreserved bottles of the requested analysis. <br /> 4. After the sample is collected, the lysimeter vacuum is reset to the manufacturer's <br /> recommended value. The lysimeter is also tested to evaluate potential leaks that may <br /> cause vacuum pressure loss. <br /> B-6 Leachate Monitorinij <br /> 1. The leachate riser or wells are first opened and allowed to equilibrate with the <br /> atmosphere. <br /> 2. The leachate elevation is then measured from a set location using a conductivity-based <br /> water-level meter. The level is generally measured from a surveyed mark on the north <br /> rim of the casing. <br /> 3. A leachate sample is then collected using a clean, disposable bailer. <br /> 02002PROP.ENV/STO5P174/DH:Iv Page B-6 <br /> ©2005 Kleinfelder,Inc. May 16,2005 <br />