Laserfiche WebLink
File No. 3359-44 • • <br /> 16 March 1995 Page 1 <br /> BACKGROUND will be placed in an ice chest and transported with <br /> appropriate chain-of-custody documents to WEST <br /> According to information provided verbally by the Laboratory for analysis. The borings will be sealed <br /> City of Ripon personnel, a 500-gallon-capacity with a cement slurry following sample collection. <br /> underground gasoline storage tank and pump were <br /> removed from the city's corporation yard on To avoid potential cross contamination, the hand <br /> California Street. The tank had contained supreme auger and drive sampler will be decontaminated <br /> leaded gasoline. The site location is shown on between sampling intervals and borings. <br /> Figures 1 and 2. The tank removal occurred Decontamination will be performed by washing <br /> approximately 15 years ago. Figure 3 includes the with a trisodium phosphate solution and rinsing <br /> former location of the underground fuel storage with distilled water. <br /> tank and associated pump. <br /> ANALYZE SAMPLES <br /> Apparently there were no soil samples collected <br /> from the tank excavation to document that no The soil samples will be analyzed for the following <br /> petroleum contamination was present. The parameters using the respective analytical method: <br /> objective of the proposed soil investigation is to <br /> collect and analyze soil samples from the areas that Parameter Method <br /> would represent the tank excavation limits. Gasoline EPA method 8015 <br /> Benzene EPA method 8020 <br /> DRILL SOIL BORINGS Toluene EPA method 8020 <br /> Ethylbenzene EPA method 8020 <br /> Two soil borings will be drilled. One in the former Xylenes EPA method 8020 <br /> underground fuel storage tank location and one in Lead EPA method 6010 <br /> the former pump location. The borings will be <br /> drilled using a hand auger. The boring depth will PREPARE REPORT <br /> be to 15 feet, assuming that the planned hand <br /> augering method does not encounter refusal at a After we complete the field work and obtain the <br /> shallower depth. This depth should be below the analytical results we will prepare a report. This <br /> bottom of the tank excavation since the tank report will document field and laboratory <br /> diameter most likely was approximately 4 feet. procedures, results, conclusions, and our <br /> And, according to a representative of the City of recommendations for additional investigative work <br /> Ripon, the tank was buried approximately 3 feet or remediation,if-warranted. <br /> below the ground surface. The boring at the <br /> former pump location will also be drilled to a <br /> depth of up to 15 feet. <br /> Two soil samples will be collected from each bore <br /> hole. One sample will be collected from the base <br /> of each boring. An additional sample will be <br /> collected if evidence of petroleum contamination <br /> is detected at shallower depths. If no evidence of <br /> contamination is detected, then a sample from 10 <br /> feet will be collected. Soil samples will be <br /> collected using a drive sampler equipped with <br /> brass sampling tubes. After removing the tubes <br /> from the drive sampler, the ends will be covered <br /> with Teflon tape and plastic end caps. Samples <br />