Laserfiche WebLink
STALLWORTH AUTO DET '�L Page 2 of 2 <br /> yp� <br /> r s 250 Feel r > 250 Feet ands 1 ,000 Feet r Unknown <br /> I <br /> 2. Media Specific Criteria: Petroleum Vapor intrusion to indoor Air - The site considered low-threat Por the vapor-intrusion-to-air pathway dsite- NO <br /> specific conditions satisfy items 2a, 2b, or2c- CLEAR SECTION ANSWERS <br /> EXEMPTION - Active Commercial Petroleum Fueling Facility r YES r NO <br /> Does the site meet any of the Petroleum Vapor Intrusion to Indoor Air specific criteria scenarios? r YES r NO <br /> ADDITIONAL QUESTIONS - Please indicate only those conditions that do not meet the policy criteria: <br /> Soil Gas Samples : <br /> r No Soil Gas Samples r Taken Incorrectly <br /> Exposure Type : <br /> C Residential r Commercial <br /> Free Product ; <br /> r In Groundwater r In Soil r Unknown <br /> TPH in the Bioadenuation Zone : <br /> r > 100 mg/kg is Unknown r Soil samples not taken at two depths within 5 ft. zone (only for Scenario 4 with BioZone) <br /> Bioaftenualion Zone Thickness : <br /> r < 5 Feet (No BioZone) r 2 5 Feel and < 10 Feet r 210 Feet and < 30 Feet r 2 30 Feet r 30118 ioZone Compromised TPH > I0omglkg r Unknown <br /> 02 Data in Sloattenuation Zone : <br /> r No Oz Data r02 < 4% rOz24% <br /> Benzene in Groundwater : <br /> r 2 100 poll and < 1,000 pgll r >- 1,000 pg/1 r Unknown <br /> Soil Gas Benzene <br /> r a 85 pg/m3 antl < 280 pglm3 r 2 280 Pg/m3 end < 85,000 pg/m3 r 2 85,000 pg/m3 antl < 28QDoo Pg/m3 r 2 280,000 pglm3 r Unknown <br /> Soil Gas EthylBenzens : <br /> r21,10Opg/m3and < 3,600pg/m3 r23,60Opg/m3and < 1,100,000pg/m3 r' 21 ,100,00pglm3and < S600,0WPg/m3 r23,600,000P9/m3 CUnknown <br /> Sol] Gas Naphthalene : <br /> r 2 93 pglm3 and < 310 pg/m3 r2 310 pg/m3and < 93,000 gg/m3 r 2 93,000 pg/m3 and <310,000 pgim3 r 2 310,000 pg/m3 r Unknown <br /> 3, Media Specific Criteria: Direct Contact and Outdoor Air Exposure - The site is considered low-threat for direct contact andoutdoorairexposure NO <br /> ifitmeets 1, 2, or3 below. - CLEAR s CTION <br /> EXEMPTION - The upper 10feet of soil isfree ofpencleum contamination r YES r NO <br /> Does theatre meet any of the Direct Contactand Outdoor Air Exposure criteria scenarios? r YES is NO <br /> ADDITIONAL QUESTIONS - Please indicate only Mose conditions that do not meet the policy criteria: <br /> Exposure Type : <br /> r Residential r Commercial r Utility Worker <br /> Petroleum Constituents in Sol : <br /> r 5 5 Feet togs r >5 Fact togs and sm Feet bgs r Unknown <br /> Soil Concentrations of Benzene ; <br /> r > 1.9 mglkg and s 2.6 mgrkg r > 28 m9/kg and < 8.2 mg/kg r > 8.2 mgtko and s 12 mglkg r > 12 mg/kg and < 14 mg/kg r > 14 mg/kg r Unknown <br /> Soil Concentrations of EthylBenzene : <br /> C' > 21 mg/kg and s 32 mglkg r > 32 mg/kg and s 89 mglkg r > 89 mg/kg and s 134 mglkg r > 134 mglkg and < 314 mglkg r > 314 mglkg (: Unknown <br /> Soil Concentrations of Naphthalene : <br /> r > 9.7 mglkg and s 45 mg/kg r > 45 mglkg and s 219 mg/kg r > 219 mg/kg IVUnknown <br /> Soil Concentrations of PAH : <br /> r > 0.063 mglkg and s 0,68 mglkg r > 0.68 mglkg and s 4.5 mglkg r > 4.5 mg/kg is Unknown <br /> Area of Impacted Soil : <br /> r Area of Impacted Soil > 82 by 82 Feel r Unknown <br /> Additional Information <br /> Should this case be closed in spite of NOT meeting policy criteria? r YES r NO <br /> SPELL CHECK <br /> i Save in Progress Save as Final <br /> LOGGED IN AS MAMASITAUM CON1691G ACKER HELP <br /> https://geotraelcer.waterboards.ca.gov/regulators/screens/closure—Policy.asp?global_id=TO.. . 7/24/2013 <br />