Laserfiche WebLink
. FOOTHILL <br /> ENGINEERING <br /> 12793 PADDY CREEK LANE 1-00I. CA 95240 <br /> PH (209) 368-9381 FAX (209) 367-1163 <br /> Mr Michael Infurna <br /> San Joaquin County Public Health Services January 2, 20 � �1 <br /> 304 E Weber Third Floor U <br /> Stockton, CA 95202 <br /> SAN o7 2002 <br /> Subject Mrs Helen Higgins / Vague Cleaners ENVIRONMENTAL HEALTH <br /> 2315 N California Street pgMIT/SERVICES <br /> Stockton, CA Site code 31032 <br /> Global ID T0607700741 <br /> Dear Mr Infurna <br /> Please find below the report of the findings <br /> REPORT OF FINDINGS FOR THE INSTALLATION OF <br /> MONITORING WELLS MW-5A AND MW-5B <br /> • SITE HISTORY <br /> The site has along history of use as a cleaning establishment and presently has the same use On June <br /> 6, 1996,Thorpe Oil removed two empty underground storage tanks from the property under a permit <br /> from the PHS/EHD Soil samples from the tank excavation were obtained using standard methods and <br /> locations The sample from under Tank 41 was taken at a depth of+/- eight feet The sample from <br /> Tank #2 was taken at a depth of+/- nine feet Both these samples and samples from the excavation <br /> spoil showed evidence of hydrocarbon contamination(See map enclosed) All of the above samees <br /> were analyzed by GeoAnalytical Laboratories,Inc The location ofTank#1 is between two structures <br /> and is 25' from the closest access point by drilling equipment Tank#2 can be accessed by vertical <br /> drilling equipment <br /> Phase 1 ofthe Site Investigation required drilling a slant soil boring under Tank#1 and a vertical soil <br /> bore at the location of Tank #2 ( See the attached soil and water analysis for BH#1 and MW#1) <br /> Phase 2 of the Site Investigation was conducted to define the vertical and horizontal extent of the <br /> contamination plume It was completed on 5/28/98 with the installation of MW#2S, MW42D, <br /> MW#3 S,MW#3D,and MW#4S,MW#4D A double monitoring well was installed in each location <br /> The shallow wells(noted by the"S"letter)had a total depth of+/-55'and the deep monitoring wells <br /> had a total depth of+/-75' The original set of water samples was made on 6/11/98(see water sample <br /> analysis, attached) <br /> The installation ofmonitoring wells MW-5A&B was first attempted onl 0/10/2001 in the sidewalk on <br /> the eastside ofCalifornia Strut On this first attempt a cable owned by Williams Communications was <br /> struck by the drill auger at a depth of 8 5 feet The cable was cut and the soil bore abandoned after it <br /> was determined that the fiber cable was not in operation The cable was 38"from it's marked location <br /> as determined by USA The cable had been installed by thejacking method and was not in use at the <br /> I <br />