Laserfiche WebLink
TABLE 1 • <br /> Groundwater Elevation and Analytical Data <br /> ARCO Service Station No.2186 <br /> 3212 North California Street,Stockton,California <br /> TOC Static Water[1] Screen Groundwater Ethyl- Total <br /> Well Sample Elevation Level Interval Elevation Groundwater TPHg Benzene Toluene benzene Xylenes MtBE[3] <br /> Sample No. Date ft msl ftbs ftbs ft msl Flow Direction N P91L p P91L p Observations <br /> VW-3B 09/13/01 [8] 46.19 -31.18 E-NE <50 <0.5 <0.5 <0.5 <0.5 90[4] No FP,No S <br /> (cont) 12/1112001 43.41 -28.40 NE <50 <0.50 <0.50 <0.50 <0.50 200[4] No FP,No S <br /> 3/14/2002 40.37 -25.36 E-NE <50 <0.50 <0.50 <0.50 <0.50 26[4] No FP,No S <br /> 6/19/2002 42.71 -27.70 E-NE 460[7] <0.50 <0.50 <0.50 <0.50 1,500[4] No FP,No S <br /> 9/12/2002 49.60 -34.59 E-NE 320 <2.5 <2.5 <2.5 <2.5 140 No FP,No S <br /> 12/3/2002 46.60 -31.59 E-NE <500 <5.0 <5.0 <5.0 <5.0 69 No FP,No S <br /> 3/11/2003 46.51 -31.50 NE 380 <2.5 <2.5 <2.5 <2.5 370 No FP,No <br /> 6/9/2003 42.39 -27.38 E-NE 2,600 <10 <10 <10 <10 6,900 No FP,No <br /> 9/17/2003 51.62 -36.61 NE 11OR <5.0 <5.0 <5.0 <5.0 210 No FP,No S <br /> 12/11/2003 46.38 -31.37 NE-SW 16,000 1,100 930 1,100 4,300 3,500 No FP,No S <br /> Notes: <br /> < = Below detection limit for the analytical method used. msl = mean sea level <br /> = Raised MRL due to high analyte concentration requiring sample dilution. MtBE = Methyl tert-butyl ether. <br /> " = Reporting limit raised due to matrix interference. NA = Not analyzed. <br /> bgs = below ground surface NM = Not measured. <br /> FP = Free product.Measured in feet. NS = Not sampled. <br /> ft =feet S = Sheen. <br /> TOC =Top of Casing <br /> [i]Measured below top of casing. TPHg = Total petroleum hydrocarbons as gasoline(reported as GRO-gasoline range organics) <br /> [2]Measured from ground surface. pg/L = micrograms per Liter <br /> [3]MtBE was analyzed using USEPA Method 8020. <br /> [4]M18E was analyzed using USEPA Method 8260. <br /> [5]Chromatogram Pattern:Weathered Gasoline C6-C-12 <br /> [6]Sample analyzed outside USEPA recommended hold time <br /> [7]Hydrocarbon pattern is present in the requested fuel quantitation range,but does not resemble the pattern of the requested fuel. <br /> [8J On the chain-of-custody forms,samples were identified as MW-18,MW-2B,and MW-313,respectively <br /> Data Qualifier Definitions: <br /> U The analyte was analyzed for,but was not detected above the sample reporting limit. <br /> J The analyte was positively identified;the associated numerical value is the approximate concentration of the analyte in the sample. <br /> N The analysis indicates the presence of an analyte for which there is presumptive evidence to make a"tentative identification." <br /> NJ The analysis indicates the presence of an analyte that has been"tentatively identified"and the associated numerical value represents its approximate <br /> concentration. <br /> UJ The analyte was not detected above the reported sample reporting limit. However,the reported reporting limit is approximate and may or may not <br /> represent the actual limit of quantitation necessary to accurately and precisely measure the analyte in the sample. <br /> R The sample results are rejected due to identification or other analytical issues. <br /> ND Not detected above reported detection limit <br /> KAWpocess16l5 5P ARCC%02i watarteam oTn 03%2188 GWMR 4CM Page 8 of 8 <br />