Laserfiche WebLink
Table A-2 <br /> Soil Vapor Extraction System Emission Data <br /> • ARCO Service Station#2186 <br /> 32212 N California Street,Stockton,California <br /> System Data GRO Benzene <br /> Effluent Effluent <br /> Hour Meter Average Concen- Emission Destruction Concen- Emission Destruction is System <br /> Sample Date Reading Flow Rate tration Rate Efficiency tration Rate Efficiency In Compliance <br /> ID Sampled (hours) (scfm) (ppmv) (lbs/day) (percent) (ppmv) (Ibs/day) (percent) with AQMD <br /> EFFL 08/30/04 4 5 950 <14 000 100% <0 15 0 000 NC Yes <br /> EFFL 06/24/03 9 4 --- System shutdown for excessive noise <br /> EFFL 11/30/04 00 1957 <14 000 100% <0 15 0 000 NC Yes <br /> EFFL 12/09/04 2162 1090 <14 000 100% <0 15 0 000 NC Yes <br /> EFFL 01/06/05 5430 1180 <14 000 100% <0 15 0 000 100% Yes <br /> EFFL 02/02/05 1,0593 1250 <14 000 100% <0 15 0 000 NC Yes <br /> EFFL 03/07/05 1,7996 1280 <14 000 100% <0 15 0 000 NC Yes <br /> scfm =Standard cubic feet per minute <br /> ppmv =Parts per million by volume <br /> Ibs =Pounds <br /> =Not applicable or not analyzed <br /> <0 31 =Less than indicated laboratory reporting limit <br /> NC =Not calculated due to non-detect influent concentrations <br /> Permit limits VOC<0 9 lbs/day, Destruction efficiency n=95% <br /> 2186 O&M Tables 1005 <br /> Table A-2 Page 1 of 1 <br />