Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS. USING THE FOLLOWING EQUATION: <br /> DO NOT SAMPLE WELL FOR P= a r2h x 7.48 x 3 <br /> DISSOLVED CONSTITUENTS. where: <br /> P= calculated purge volume (gallons) <br /> a=3.14 <br /> r=radius of well casing in feet <br /> h= height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMITS THE CALCULATED PURGE VOLUME WHILE <br /> MONITORING GROUNDWATER <br /> OF DRYNESS BEFORE REMOVING <br /> CALCULATED PURGE VOLUME STABILIZATION INDICATOR PARAMETERS <br /> (pH, CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME. <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA. WELL RECHARGES TO A LEVEL <br /> pH =± 0.1 pH units SUFFICIENT FOR SAMPLE <br /> COND. =± 10% COLLECTION WITHIN 24 HOURS <br /> TEMP. =± 1.0 OF OF EVACUATION TO DRYNESS. <br /> YES NO YES NO <br /> WELL PURGING CONTINUE PURGING;EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET; ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER, MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING. INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING. <br /> STABILITY. SAMPLING. <br /> FIGURE <br /> INTERNATIONAL <br /> TECHNOLOGY MONITORING WELL PURGING PROTOCOL A-1 <br /> CORPORATION <br />