Laserfiche WebLink
MONITORING WELL PURGING PROTOCOL <br /> t <br /> MEASURE AND RECORD DEPTH TO WATER AND <br /> WELL TOTAL DEPTH <br /> CHECK FOR FLOATING PRODUCT <br /> YES NO <br /> MEASURE AND DOCUMENT CALCULATE PURGE VOLUME BY <br /> FLOATING PRODUCT THICKNESS. USING THE FOLLOWING EQUATION: <br /> P =a rzh x 7.48 x 3 <br /> DO NOT SAMPLE WELL FOR <br /> DISSOLVED CONSTITUENTS. where: <br /> P= calculated purge volume (gallons) <br /> n =3.14 <br /> r= radius of well casing in feet <br /> h=height of water column in feet <br /> EVACUATE WATER FROM WELL EQUAL TO <br /> WELL EVACUATED TO PRACTICAL LIMITS <br /> THE CALCULATED PURGE VOLUME WHILE <br /> OF DRYNESS BEFORE REMOVING MONITORING GROUNDWATER <br /> CALCULATED PURGE VOLUME STABILIZATION INDICATOR PARAMETERS <br /> (pH, CONDUCTIVITY,TEMPERATURE)AT <br /> INTERVALS OF ONE CASING VOLUME. <br /> NO YES <br /> FINAL TWO SETS OF GROUNDWATER <br /> STABILIZATION INDICATOR PARAMETER <br /> MEASUREMENTS MEET THE FOLLOWING <br /> CRITERIA: WELL RECHARGES TO A LEVEL <br /> pH = ±0.1 pH units SUFFICIENT FOR SAMPLE <br /> COND. _ ± 10 % COLLECTION WITHIN 24 HOURS <br /> TEMP. _ + 1.0 ' OF EVACUATION TO DRYNESS. <br /> YF 5 NO <br /> kYES NO <br /> WELL PURGING CONTINUE PURGING; EVACUATE FIELD TEST FIRST RECORD WELL <br /> CRITERIA MET; ADDITIONAL CASING VOLUME RECHARGE WATER FOR AS DRY FOR <br /> PROCEED TO OF WATER,MONITORING INDICATOR PARAMETERS, PURPOSES OF <br /> WELL SAMPLING. INDICATOR PARAMETERS FOR THEN PROCEED TO WELL SAMPLING. <br /> STABILITY. ISAMPLING. <br /> FIGURE <br /> INTERNATIONAL. <br /> TECHNOLOGY MONITORING WELL PURGING PROTOCOL A-1 <br /> CORPORATION <br />