My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0012820
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CALIFORNIA
>
3212
>
3500 - Local Oversight Program
>
PR0544153
>
ARCHIVED REPORTS XR0012820
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 10:48:04 AM
Creation date
2/15/2019 9:53:30 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0012820
RECORD_ID
PR0544153
PE
3528
FACILITY_ID
FA0006773
FACILITY_NAME
ARCO 02186
STREET_NUMBER
3212
Direction
N
STREET_NAME
CALIFORNIA
STREET_TYPE
ST
City
STOCKTON
Zip
95204
APN
12532001
CURRENT_STATUS
02
SITE_LOCATION
3212 N CALIFORNIA ST
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mr Kyle Christie Project 0805-147 01 <br /> August 4, 1995 <br /> Page 3 <br /> Groundwater Monitoring Well Installation <br /> In the event that hydrocarbons are present in soil samples collected from the borings <br /> downgradient from the USTs (using a photoioruzation detector [PID] and field <br /> observations), and based on subsurface conditions, EMCON will observe a licensed well <br /> driller redrill the boring with a 10-inch-diameter auger and two drill 10-Inch-diameter soil <br /> borings near the northwestern and southeastern property boundaries (see Figure 2). The <br /> borings will be drilled to a depth of approximately 55 feet bgs or 15 feet below fust <br /> encountered groundwater However, if a 5-foot thick clay layer Is encountered less than <br /> 15 feet bgs, the drilling will be terminated within the clay unit <br /> Three 4-inch-diameter groundwater monitoring wells will be Installed in the borings The <br /> wells will be constructed using 0 02 slotted screen The 0 02 screen will be placed from <br /> approximately 15 feet below first encountered groundwater and will extend up to five feet <br /> above first encountered groundwater Number 3 sand will be used as the filter pack <br /> Undisturbed soil samples will be collected from the two soil bonngs drilled near the <br /> northwestern and southeastern property boundaries using the methods described above In <br /> addition, two soil samples from each boring will be submitted to an approved state <br /> certified laboratory and analyzed for TPHG and BTEX using EPA Methods 8015 and <br /> 8020, respectively <br /> Vapor Extraction Well Installation <br /> In the event that hydrocarbons are present in soil samples collected from the boring <br /> located at the northwest corner of the tank complex (using a PID and field observations) <br /> and based on subsurface conditions, EMCON will observe a licensed well driller redrill the <br /> boring with a 10-Inch-diameter auger (see Figure 2) The borings will be drilled to a depth <br /> of approximately 40 feet bgs or to fust encountered groundwater <br /> One 4-uich-diameter vapor extraction well will be installed in the boring The well will be <br /> constructed using 20 feet of 0 10 slotted screen Pea gravel will be used as the filter pack <br /> Well Development and Sampling <br /> If groundwater monitoring wells are installed, EMCON will develop and sample the <br /> groundwater monitoring wells In addition, a licensed surveyor will be contracted to <br /> survey the location of the wells with respect to mean sea level The wells will be placed on <br /> a quarterly groundwater monitoring program and analyzed for TPHG and BTEX using <br /> iEPA Methods 8015 and 602, respectively EMCON's field procedures are included in <br /> Attachment A <br /> SAC\N\Pd010805108051470IAN-941dms I <br />