Laserfiche WebLink
TABLE KEY <br /> STANDARD ABREVIATIONS <br /> -- = not analyzed,measured,or collected <br /> LPH = Iiquid-phase hydrocarbons <br /> Trace = less than 0,01 foot of LPH in well <br /> Pg/I = micrograms per liter(approx. equivalent to parts per billion,ppb) <br /> mg/l = milligrams per liter(approx, equivalent to parts per million,ppm) <br /> ND< = not detected at or above laboratory detection limit <br /> TOC = top of casing(surveyed reference elevation) <br /> ANALYTES <br /> TTF5C = benzene, toluene, ethylbenzene, and(total)xylenes <br /> DIPE = di-isopropyl ether <br /> ETBE = ethyl tertiary butyl ether <br /> MTBE = methyl tertiary butyl ether <br /> PCB = polychlorinated biphenyls <br /> PCE = tetiachloroethene <br /> TBA — tertiary butyl alcohol <br /> TCA = trichloroethane <br /> TCE = trichloroethene <br /> TPN-G = total petroleum hydrocarbons with gasoline distinction <br /> TPH-D = total petroleum hydrocarbons with diesel distinction <br /> TPPH = total purgeable petroleum hydrocarbons <br /> TRPH = total recoverable petroleum hydrocarbons <br /> TAME = tertiary amyl methyl ether <br /> 1,1-DCA = 1,1-dichloroethane <br /> 1,2-DCA = 1,2-dichloroethane(same as EDC,ethylene dichloride) <br /> 1,1-DCE 1,1-dichloroethene <br /> 1,2-DCE = 1,2-dichloroethene(cis-and trans-) <br /> NOTES <br /> 1. Elevations are in feet above mean sea level. Depths are in feet below surveyed top-of-casing. <br /> 2. Groundwater elevations for wells with LPH are calculated as: Surface Elevation- Measured Depth to Water + <br /> IDp? x LPH Thickness), where Dp is the density of the LPH, if known. A value of 0.75 is used for gasoline and <br /> when the density is not known. A value of 0.83 is used for diesel. <br /> 3. Wells with LPH are generally not sampled for laboratory analysis (see General Field Procedures). <br /> 4. Comments shown on tables are general. Additional explanations may be included in field notes and laboratory <br /> reports, both of which are included as part of this report. <br /> 5. A "J" flag indicates that a reported analytical result is an estimated concentration value between the method <br /> detection limit(MDL) and the practical quantification limit(PQL)specified by the laboratory. <br /> 6. Other laboratory flags (qualifiers) may have been reported. See the official laboratory report(attached) for a <br /> complete list of laboratory flags. <br /> 7. Concentration graphs based on tables (presented following Figures)show non-detect results prior to the Second <br /> Quarter 2000 plotted at fixed values for graphical display. Non-detect results reported since that time are plotted at <br /> reporting limits stated in the official laboratory report. <br /> 8. Groundwater vs. Time graphs may be corrected for apparent level changes due to resurvey. <br /> REFERENCE <br /> TRC began groundwater monitoring and sampling for Circle K Store 01205 in October 2003. Historical data compiled prior to <br /> . that time were provided by Gettler-Ryan Inc. <br /> f <br />