My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000771
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAMBRIDGE
>
16470
>
3500 - Local Oversight Program
>
PR0544155
>
ARCHIVED REPORTS XR0000771
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 5:26:59 PM
Creation date
2/15/2019 2:09:56 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3500 - Local Oversight Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000771
RECORD_ID
PR0544155
PE
3526
FACILITY_ID
FA0000185
FACILITY_NAME
CITY GAS & LIQUOR
STREET_NUMBER
16470
STREET_NAME
CAMBRIDGE
STREET_TYPE
ST
City
LATHROP
Zip
95330
APN
19643032
CURRENT_STATUS
02
SITE_LOCATION
16470 CAMBRIDGE ST
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
' (���Lancaster Laboratories <br /> 2425 New HoliandPke•LancasterPA17501 Explanation of Symbols and Abbreviations <br />' The following defines common symbols and abbreviations used in reporting technical data <br /> N D none detected <br /> B <br /> TNTC Too Numerous To Count MQL Below Minimum Quantitation Level <br /> MPN Most Probable Number <br /> IU International Units CP Units cobalt-chloroplatinate units <br /> umhos/cm micromhoslcm NTU nephelometric turbidity units <br /> C degrees Celsius F degrees Fahrenheit <br /> meq milliequivalents lb pound(s) <br />' 9 gram(s) <br /> u9 microgram(s) kg kilogram(s) <br /> Mg <br /> ml milliliterI liter(s)s) mils) <br /> M3 cubic meter(s) ul microliter(s) <br />' < less than-The number following the sign is the limit of quantitation, the smallest amount of analyte which can be <br /> reliably determined using this specific test <br />' > greater than <br /> J estimated value—The result falls within the Method Detection Limit(MDL)and Limit of Quantitation (LOQ) <br /> Ppm parts per million -One ppm is equivalent to one milligram per kilogram (mg/kg),or one gram per million grams For <br /> aqueous liquids, ppm is usually taken to be equivalent to milligrams per liter(mg/1), because one liter of water has a <br /> weight very close to a kilogram For gases or vapors, one ppm is equivalent to one microliter of gas per liter of gas <br /> ppb parts per billion <br />' Dry weight Results printed under this heading have been adjusted for moisture content This increases the analyte weight <br /> basis concentration to approximate the value present in a similar sample without moisture Ail other results are reported <br /> on an as-received basis <br />' US EPA CLP Data Qualifiers <br /> Organic Qualifiers Inorganic Qualifiers <br />' A TIC is a possible aldol-condensation product B Value is<CRDL, but>_IDL <br /> B Analyte was also detected in the blank E Estimated due to interference <br /> C Pesticide result confirmed by GC/MS M Duplicate injection precision not met <br /> D Compound quantitated on a diluted sample N Spike sample not within control limits <br /> E Concentration exceeds the calibration range of S Method of standard additions(MSA) used <br /> the instrument for calculation <br /> N Presumptive evidence of a compound(TICS only) U Compound was not detected <br /> P Concentration difference between primary and W Post digestion spike out of control limits <br /> confirmation columns >25% Duplicate analysis not within control limits <br /> U Compound was not detected + Correlation coefficient for MSA<0 995 <br /> X,Y,Z Defined in case narrative <br />' Analytical test results for methods listed on the laboratories'accreditation scope meet all requirements of NELAC unless <br /> otherwise noted under the individual analysis <br /> Measurement uncertainty values, as applicable, are available upon request <br />' Tests results relate only to the sample tested Clients should be aware that a critical step in a chemical or microbiological <br /> analysis is the collection of the sample Unless the sample analyzed is truly representative of the bulk of material involved, the <br /> test results will be meaningless If you have questions regarding the proper techniques of collecting samples, please contact <br /> us We cannot be held responsible for sample integrity, however, unless sampling has been performed by a member of our <br /> staff This report shall not be reproduced except in full, without the written approval of the laboratory <br /> WARRANTY AND LIMITS OF LIABILITY-In accepting analytical work, we warrant the accuracy of test results for the sample as submitted <br /> THE FOREGOING EXPRESS WARRANTY IS EXCLUSIVE AND IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR <br />' IMPLIED WE DISCLAIM ANY OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING A WARRANTY OF FITNESS FOR <br /> PARTICULAR PURPOSE AND WARRANTY OF MERCHANTABILITY IN NO EVENT SHALL LANCASTER LABORATORIES BE LIABLE <br /> FOR INDIRECT, SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES INCLUDING, BUT NOT LIMITED TO, DAMAGES FOR LOSS <br /> OF PROFIT OR GOODWILL REGARDLESS OF(A)THE NEGLIGENCE(EITHER SOLE OR CONCURRENT)OF LANCASTER <br />' LABORATORIES AND(B)WHETHER LANCASTER LABORATORIES HAS BEEN INFORMED OF THE POSSIBILITY OFS <br /> wder <br /> UCH <br /> DAMAGES We accept no legal responsibility for the purposes for which the client uses the test results No purchase order or other ordork shall be accepted by Lancaster Laboratories which includes any conditions that vary from the Standard Terms and Conditions d <br /> Waster Laboratories and we hereby object to any conflicting terms contained in any acceptance or order submitted by cliof <br /> ent <br />' <br /> 376801 <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.