My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000659
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000659
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 9:22:49 PM
Creation date
2/15/2019 3:11:18 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000659
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
246
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
tl <br /> { { E <br /> r <br /> ' i c <br /> i <br /> 15 October 2000 <br /> AGE-NC Project No 96-0232 <br /> 1 Page 6of15 <br /> 4.0. AQUIFER PUW TEST <br /> On 20,21 and 24 July 2000, aquifer draw-down pump testing was performed at the site to evaluate <br />' general ground water aquifer charactenstics and to evaluate ground water draw-down at various <br /> pumping rates <br /> 41 FIRST ZONE AQUIFER PUMP TESTS, 20 AND 24 JULY 2000 <br />' The first stage of constant rate ground water pump testing consisted of extracting ground water <br /> utilizing a Grundfos Redi-Flo pump from EW-2 in the Fust Zone Aquifer at a rate of 4 0 GPM, the <br /> second stage consisted of extracting ground water at a rate of 6 6 GPM, the third stage consisted of <br /> extracting ground water at a rate of 10 GPM <br /> The first stage pump test (4 GPM) consisted of extracting ground water from well EW-2 utilizing <br /> a 2-inch diameter submersible Grundfos Redi-flo pump and was terminated after 90-minutes of <br /> pumping when the pump malfunctioned by over-heating The second stage pump test(6 6 GPM)was <br /> initiated by extracting ground water from well EW-2 for 600 minutes utilizing a 4-mch diameter <br /> submersible Grundfos Redi-flo pump, the test was terminated after 600 minutes of ground water <br /> extraction because the 5,900-gallon Baker tank was at full capacity The third stage pump test (10 <br />' GPM) consisted of extracting ground water from well EW-2 utilizing the 4-inch diameter <br /> submersible Grundfos Redi-flo pump and was terminated after 120 minutes of groundwater <br /> extraction because the 5,900-gallon Baker tank was at full capacity The pump test utilized pressure <br />' transducers that were deployed in wells MW-1,EW-1,EW-2 and EW-3 A plot of draw-down versus <br /> { time for the first, second and third stage of pump testing are included in Appendix G <br /> Draw-down versus distance for wells MW-1, EW-1 and EW-2 were graphed on seam-logarithmic <br /> paper for pump test stages 1, 2 and 3, utilizing the Time-Drawdown Method (Jadob straight-line <br />' method),the transmissivity and storativity for aquifer pump test stages 1,'2 and 3 were determined <br /> (Appendix F) Ground water levels in wells EW-3, MW-6A and MW-9A did not appear to be <br /> influenced during the pump tests <br />' During the first stage pump test(4 0 GPM), the greatest ground water drawn-down in extraction well <br /> EW-2 was observed at 5 25 feet after 50 minutes of pumping operation, draw-down was observed <br />' in wells EW-1 (located 11 feet towards the north-northwest) at 0 92 feet and iii MW-1 (located 7 feet <br /> towards the north) at 0 90 feet Minor decreases in ground water levels in well EW-3 (located'4 feet <br /> towards the west and screened 40 to 50 feet bsg)were observed at as much as 0 07 feet, in MW-6A <br />' (located 73 feet towards the south) at as much as 0 03 feet and in MW-9A (located 45 feet towards <br /> . the west-southwest) at as much as 0 02 feet Results of the stage 1 pump test ground water draw- <br /> down levels are summarized in Table 2 Utilizing data collected from well EW-1,EW-2 and MW--1, <br /> Advanced GeoCaviroomentai,Inc. <br /> 1 , <br />
The URL can be used to link to this page
Your browser does not support the video tag.