ARCHIVED REPORTS XR0000660
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000660
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 7:20:55 PM
Creation date
2/15/2019 3:12:33 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000660
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
223
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
31 August 2000 <br /> AGE Project No 96-0232 <br /> Page 12 of 25 <br />' submersible Grundfos Redi-flo pump and was terminated after 120 minutes of ground water <br /> extraction because the 5,900-gallon Baker tank was at full capacity The pump test utilized pressure <br /> transducers that were deployed in wells MW-1,EW-1,EW-2 and EW-3 A plot of draw-down versus <br /> I time for the first stage pump test and data logs are included in Appendix B, a plot of draw-down <br /> versus time for the second stage pump test and data logs are included in Appendix C, a plot of draw- <br /> down versus time for the third stage pump test and data logs are included in Appendix D <br /> Draw-dawn versus distance for wells MW-1, EW-1 and EW-2 were graphed on semi-logarithmic <br /> paper for pump test stages 1, 2 and 3, utilizing the Time-Drawdown Method (Jacob straight-line <br /> I method), the transmissivity and storativity for aquifer pump test stages 1, 2 and 3 were determined <br /> (Appendix E) Calculations for pump test stages 1, 2, and 3 are summanzed in Table 6 Ground <br /> water levels in wells EW-3,MW-6A and MW-9A did not appear to be influenced during the pump <br />' tests <br /> During the first stage pump test(4 0 GPM),the greatest ground water drawn-down in extraction well <br />' EW-2 was observed at 5 25 feet after 50 minutes of pumping operation, draw-down was observed <br /> in wells EW-1 (located 11 feet towards the north-northwest)at 0 92 feet and in MW-1 (located 7 feet <br /> towards the north) at 0 90 feet Minor decreases in ground water levels in well EW-3 (located 4 feet <br /> lie towards the west and screened 40 to 50 feet bsg)were observed at as much as 0 07 feet, in MW-6A <br /> (located 73 feet towards the south) at as much as 0 03 feet and in MW-9A (located 45 feet towards <br /> the west-southwest) at as much as 0 02 feet Results of the stage 1 pump test ground water draw- <br /> down levels are summarized in Table 2 Utilizing data collected from well EW-1,EW-2 and MW-1, <br /> a transmissivity value was calculated at 774 gal/day-ft, a specific yield value is calculated at 0 034 <br /> I and a radius of influence is projected at 17 feet utilizing a semi-loganthmic plot of draw-down <br /> versus distance (Appendix E) <br />' During the second stage pump test(6 6 GPM), the greatest ground water drawn-down was observed <br /> in extraction well EW-2 at 8 26 feet after 600 minutes of pumping operation, draw-down was <br /> observed in wells EW-1 at 1 85 feet and in MW-1 at 1 98 feet Minor decreases in ground water, <br />' levels from well EW-3 were observed at as much as 0 14 feet, in MW-6A at as much as 0 03 feet <br /> and in MW-9A at as much as 0 05 feet Results of the stage 2 pump test ground water draw-down <br /> levels are summarized in Table 3 Utilizing data collected from well EW-1, EW-2 and MW-1, a <br />' transmissivity value was calculated at 718 gal/day-ft, a specific yield value is calculated at 0 21 and <br /> a radius of influence is projected at 20Y2 feet utilizing a semi-logarithmic plot of draw-down versus <br /> distance(Appendix E) <br />' Dunn the third stage um test(10 0 GPM), the greatest ground water drawn-down was observed <br /> During g pump <br /> in extraction well EW-2 at 12 06 feet after 50 minutes of pumping operation, draw-down was <br />' observed in wells EW-1 at 2 81 feet and in MW-1 at 3 08 feet Minor decreases in ground water <br /> levels in well EW-3 were observed at as much as 0 11 feet, in MW-6A at as much as 0 12 feet and <br /> I in MW-9A at as much as 0 05 feet Results of the stage 3 pump test ground water draw-down levels <br /> Advanced GeoEnvironmental,Inc. <br /> I <br />