Laserfiche WebLink
15 January 2001 <br /> AGE-NC Project No 96-0232 <br />' Page 20 of 20 <br />' through MW-13, municipal water wells CSA-1 and CSA-2 and domestic water wells DW-1 <br /> and RDW-1 <br /> • Continued coordinated quarterly ground water sampling events with Three B's Truck Plaza <br />' • Installation of fuel-dispenser containment pans beneath each fuel dispenser at the Flag City <br /> Chevron site <br />' • Continued selective ground water extraction in alternating weekly shafts from extraction <br /> wells located in the south trench-line (EW-2, EW-4, EW-6 and EW-9) and wells located in <br />' the north trench-lane (EW-5, EW-7, EW-8 and EW-10) <br />' 120 LIMITATIONS <br /> Our professional services were performed using that degree of care and skill ordinarily exercised by <br />' environmental consultants practicing in this or similar localities The findings were based mainly <br /> upon analytical results provided by an independent laboratory Evaluations of the geologic/hydro- <br /> geologic conditions at the site for the purpose of this investigation are made from a limited number <br /> of available data points (ground water samples), and subsurface conditions may vary away from <br /> these data points No other warranty, expressed or implied, is made as to the professional <br /> recommendations contained an this report <br /> Advanced GeoEnvironmental,Inc <br /> i <br />