ARCHIVED REPORTS XR0000680
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000680
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 6:32:04 PM
Creation date
2/15/2019 3:56:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000680
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
47
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r'_RDER NO 5-00-119 2 <br /> ATTACHMENT B <br /> MONITORING AND REPORTNG PROGRAi'A <br /> GENERAL ORDER FOR DIS CHARGE TO <br /> 'lSLTRFACE WATERS OF GROUND WATER <br /> FROM CLEANUP OF PETROLEUM FUEL POLLU'17-ON <br /> EFFLUENT MONITORING <br /> Eluent samples shall be collected from the last connection through which wastes can be admattea into <br /> the outfall Effluent samples should be representative of the volume and nature of the discharge Tame <br /> and specific location of collection of the grZo sanaplc- shall be recorded The following shall constitute <br /> the eluent monitoring program <br /> Type of Samphng <br /> Constituents Units Sample Freguencv <br /> Flow mad continuous Monthly - <br /> Specific Conductivity umhos/cm Grab Monthly <br /> pH pH units Grab Monthly <br /> Temuerature OF Crab Monthly <br /> Total Dissolved Solids Mg/1 Grab Monthly <br /> Total Petroleum Hydrocarbons mg../I Grab Monthly** W <br /> (Gasoline, diesel, motor oil) <br /> Benzene 4g11 Crab Monthly** <br /> Toluene µg/1 Grab Monthly* <br /> 0Ethylbenzene gwl Crab Monthiy** <br /> Xylene (Total) µIwl Grab Monthly** <br /> MTBE lag/, Grab Monthly** <br /> Leaci (totaI)* µg/1 Grab Monthly" �-- <br /> Bicassay*** % Survival Grab Quarterly <br /> Methanol PL=-/l Grab Monthly* <br /> Ethanol µg/I Grab Monthly** <br /> Ternary Butyl Alcohol (TBA) µg/1 Grab Monthly** <br /> Di-Isopropyl Ether(DIPE) µg/l Grab Monthly** <br /> Ethyl Tertiary Butyl Ether(ETRE) µg11 Grab Monthly*" <br /> Tertiary Arnyl Methyl Ether µ6l1 Grab Monthly** <br /> (TAME) M 4+ti i I� �• <br /> �lJ r'+ A � <br /> * If lead isnot detected m the first 2sampling events, then testing may be discontinued thereafter <br /> ** 1) Analyses shall be conducted weekly for four consecutive weeks following mitral discharge from the treatment <br /> system 2) If any sample shows detectable TPH, Benzene,Toluene, Etbylbenzene, Xylene,lVME or other oxygerates <br /> the Discharger shall immediately resample and reanalyze the effluent for the detected constituent(s), and shall continue <br /> sampling the effluent on a weakly basis until the coustrtuent(s) concentrations are below permitted levels 3) If three <br /> consecutive monthly sampling events result in non detectable concentration, at appropriate detection limits, then the <br /> sampling frequency shall be reduced to Quarterly 4) If a detectable concentration is determined to be present m the <br /> wastewater the frequency will revert back to monthly 5) If a constituent is not present in the influent sample, then the <br /> testing for that constituent may be discontinued until detected in the mfluent <br /> *'* The acute bioassays samples shall be analyzed using EPA)600/4_90/027F, or later amendment with Board staff <br /> • approval Temperature ana pH shall be reworded at the time of bioassay sample collection. Test species shall be <br /> fathead minnows (Prmenhales prcmelas),with no pH adjustment unless approved by the Executive Officer <br />