My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
ARCHIVED REPORTS XR0000690
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
C
>
CAPITOL
>
6421
>
2900 - Site Mitigation Program
>
PR0522496
>
ARCHIVED REPORTS XR0000690
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/15/2019 10:42:20 PM
Creation date
2/15/2019 4:10:40 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
ARCHIVED REPORTS
FileName_PostFix
XR0000690
RECORD_ID
PR0522496
PE
2957
FACILITY_ID
FA0015317
FACILITY_NAME
FLAG CITY CHEVRON
STREET_NUMBER
6421
STREET_NAME
CAPITOL
STREET_TYPE
AVE
City
LODI
Zip
95245
APN
05532024
CURRENT_STATUS
02
SITE_LOCATION
6421 CAPITOL AVE
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
WNg
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
196
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i1 <br /> Problem Assessment Report <br /> FLAG CITY CHEVRON <br /> 6421 Capitol Avenue, Lodi, California <br /> 1.0. INTRODUCTION AND SCOPE OF WORK <br /> At the request of Mr Richard Bokides of the Bokides Family Limited Partnership, Advanced <br /> GeoEnvironmental, Inc (AGE), has prepared this Problem Assessment Report (PAR) for 6421 <br /> Capitol Avenue (site), Lodi, California The location of the site is illustrated in Figure 1 A plan of <br /> the site is illustrated in Figure 2 <br /> The scope of work for this PAR is to summarize the preliminary investigation and evaluation of the <br /> subsurface release on the site, to describe the lateral and vertical extent of fuel components impact <br /> to soil and ground water and to evaluate the feasibility and costs of several remedial action <br /> alternatives for petroleum-hydrocarbon impact to soil and ground water at the Flag City Chevron <br /> site This PAR was prepared in accordance with guidelines established by the Regional Water <br /> Quality Control Board - Central Valley Region (RWQCB-CVR) for preliminary investigation and <br /> evaluation of underground storage tank (UST) sites <br /> 2.0. BACKGROUND <br /> The site is located at the northeast intersection of Capitol Avenue and Thornton Road,approximately <br /> 500 feet south of California State Highway 12 and approximately 5 miles west of Lodi, California <br /> (Figure 1) The site is located in the northeast quarter of Section 14, Township 3 North, Range 5 <br /> East, Mount Diablo Base and Meridian (Temmous Quadrangle, 7 5-Minute USGS Topographic <br /> Senes, 1978, photo revised 1993) <br /> 2 1 SITE LOCATION AND DESCRIPTION <br /> The property is currently utilized as a Chevron fueling facility and a mini-market The site consists <br /> of one building structure, six fuel dispensers, three 12,000-gallon gasoline USTs and one 12,000- <br /> gallon diesel UST (Figure 2) <br /> The property west of the site(Three B's Truck Plaza- 14749 North Thornton Road)is approximately <br /> 200 feet west-northwest of the Flag City Chevron site and is currently utilized as a mini-mart and <br /> truck stop (Figure 3) <br /> 2 2 UNDERGROUND STORAGE TANK REMOVAL FLAG CITY CHEVRON <br /> On 31 March 1995, three 12,000-gallon gasoline USTs and one 12,000-gallon diesel UST were <br /> replaced at the site During excavation activities, ground water was encountered in the UST cavity <br /> Advanced GeoEn%Eronmental,Inc <br />
The URL can be used to link to this page
Your browser does not support the video tag.